Manual.ly Logo

Berbel Formline BKH FO Manual

0.0 · 0 Ratings

PDF manual · 36 Pages

English

M: QW-35-FL
page

/ 36

Loading...
31d4520dbc4c108fcdfc414b1084428186f3 page 1b
27
Maintenance
6005044_a – 07.04.2020
EN
6. Maintenance
6.1 Safety instructions for maintenance
D WARNING!
Hazard through a disregard of the maintenance
instructions!
This chapter contains important information for the safe
maintenance of the device.
☞ Read through this chapter carefully before carrying out
maintenance work on the device.
☞ Follow the safety instructions.
☞ Carry out the maintenance work as described.
y Repairs only by qualified specialist personnel.
D “1.2 Authorised target groups” (page 4).
y Electrical work only to be undertaken by qualified
electricians.
D “1.2 Authorised target groups” (page 4).
y Maintenance only by authorised users.
D “1.2 Authorised target groups” (page 4).
y No maintenance work permitted by children under
8 years old and persons who would not be able to
properly assess the hazards associated with handling the
device.
y When working at heights, ensure good stable footing
(e.g. stable stepladder).
y The hob and other parts that can be touched must be
cooled down.
y Never open the fan housing.
6.2 Maintenance
6.2.1 Changing the lamps
The device is fitted with maintenance-free LED lighting.
In the event of a fault:
☞ Please consult your dealer or customer services.
6.2.2 Replacing filter filling (with recirculating and
hybrid mode)
Odours are trapped in the filter filling in the recirculating air
filter or hybrid filter. The odour-free, cleaned room air is fed
back into the room.
Recirculating air filters and hybrid filters are maintenance-free
for up to two years.
Then filter filling must be replaced at regular intervals.
Maintenance intervals
y When the control indicator blinks - every 1000 fan
operating hours.
D “4.2.3 Filter filling indicator” (page 22).
y With odours in the exhaust air.
y With daily use, after 24 months at the latest.
y With occasional use, after 36 months at the latest.
D ATTENTION!
Danger of property damage through falling parts!
When working on the device, parts of the device or tools
could fall and damage the kitchen equipment.
☞ Protect the cooled hob and other surfaces in the cooking
area (e.g. with thick cardboard).
1.
2.
☞ Loosen the inner chimney duct on both sides from the
chimney mount.

Chat with your Berbel Formline BKH FO manual using AI

Get instant AI answers from your Berbel Formline BKH FO manual

Ask anything about the Berbel Formline BKH FO. Answers come from this manual, with the pages they are based on.

Formline BKH FO Maintenance Schedule

Remind me when maintenance is due
Every 3 weeks (with daily use)
Clean the Capillar Trap

Remove the Capillar Trap and clean it in a dishwasher or with suitable cleaning agents. Ensure it is completely dry before reinserting.

Show in the manual (page 25)
Every 24 months (daily use)
Replace filter filling (recirculating/hybrid mode)

With daily use, replace the filter filling at the latest after 24 months to maintain performance.

Show in the manual (page 27)
Every 36 months (occasional use)
Replace filter filling (recirculating/hybrid mode)

With occasional use, replace the filter filling at the latest after 36 months.

Show in the manual (page 27)
After each cooking process
Clean control panel, surfaces, upper section, bulging edge and lower section

Use a soft damp cloth with mild household cleaner. Dry with a lint-free soft cloth to prevent grease buildup.

Show in the manual (page 25)
Every 1000 operating hours
Replace filter filling (recirculating/hybrid mode)

Replace when the indicator flashes every 1000 fan operating hours or if odours persist. Reset the counter after replacement.

Show in the manual (page 27)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend Formline BKH FO?

Yes No

Frequently Asked Questions

A

This hood supports three modes: recirculated air mode for filtering and returning air, extracted air mode for venting outdoors, and hybrid mode which allows switching between the two depending on the season or cooking intensity.

Is this answer helpful?

A

The filter filling should be replaced every 1000 fan operating hours, indicated by a flashing light on the control panel. Alternatively, replace it annually with daily use or every 36 months with occasional use.

Is this answer helpful?

A

No. Electrical work must be performed by a qualified electrician, and general installation requires qualified specialist personnel due to the weight and safety risks involved.

Is this answer helpful?

A

The Capillar Trap uses centrifugal force to eject dirt particles like grease and oil from the air stream, collecting them in the upper and lower sections to keep the internal mechanism cleaner.

Is this answer helpful?

A

Yes, the device automatically shuts off after 12 hours of inactivity to save energy and ensure safety if left running unintentionally.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Supports three flexible operating modes including hybrid functionality
  • Capillar Trap efficiently separates grease and oil using centrifugal force
  • LED cooktop lighting features adjustable color temperature settings
  • Automatic run-on function extends filter life and removes residual odors
  • BackFlow technology option prevents condensate buildup
VS

Disadvantages

  • Installation strictly requires qualified electricians and specialist personnel
  • Requires regular replacement of filter fillings to maintain efficiency
  • Hybrid mode necessitates additional accessories like wall boxes
  • Heavy weight demands two persons for safe installation and removal
  • Extraction performance relies heavily on correct ducting configuration
M: QW-35-FL

Product Specification

Type

Wall hood, Chimney hood, Island hood

Color

stainless steel

Operating mode

Exhaust, Recirculation

Fan performance

371 cu ft/h

Speed settings

3, Boost

Features

Touch control, Delay auto-off, Filter saturation indicator

Fan efficiency class

A (A to G)

Lighting efficiency class

B (A to G)

Grease filter efficiency class

B (A to G)

Package contents

Charcoal filter, Chimney, Grease trap

M: QW-35-FL

Product Description

The Berbel Formline BKH FO Wall Extractor Hood Manual: A Comprehensive Guide

The Berbel Formline BKH FO Wall Extractor Hood represents a pinnacle of modern kitchen ventilation technology. Designed for private domestic use, this manual details the operation, installation, and maintenance of models ranging from the compact BKH 60 FO to the expansive BKH 120 FO. Whether you are dealing with steamy cooking sessions or intense searing, this hood offers versatile solutions to keep your kitchen air fresh and clean.

Versatile Operating Modes

One of the standout features of the Berbel Formline BKH FO is its adaptability. It supports three distinct operating modes: recirculated air mode, extracted air mode, and hybrid mode. In recirculated air mode, the hood filters odors using specialized filter fillings before returning clean air to the room, making it ideal for winter months when heat loss is a concern. For summer or heavy frying, the extracted air mode vents pollutants directly outside through ducting. The hybrid mode allows users to switch between these two options seamlessly, offering maximum flexibility based on current needs.

Advanced Features and Safety

Safety is paramount in the design of the Berbel Formline BKH FO Wall Extractor Hood Manual. The device includes a Capillar Trap that uses centrifugal force to separate grease and oil particles effectively. Additionally, optional BackFlow technology prevents condensate formation by directing a gentle airflow over the hood's underside. The control panel is intuitive, featuring LED lighting with adjustable color temperatures and an automatic run-on function that continues cleaning for ten minutes after cooking stops.

Installation and Maintenance

Installation requires qualified personnel and careful adherence to safety guidelines regarding electrical connections and structural support. The manual provides step-by-step instructions for hanging the unit, connecting accessories like window contact switches, and mounting the chimney. Regular maintenance ensures longevity; users must replace filter fillings every 1000 hours or annually and clean the Capillar Trap and lower sections regularly to prevent fire hazards. With proper care, this extractor hood remains a reliable guardian of your kitchen environment.

M: QW-35-FL

© Copyright 2026 Manual.ly