Manual.ly Logo

B.E.G. PSN-230/640/30 KNX REG Manual

0.0 · 0 Ratings

PDF manual · 4 Pages

English

M: QW-35-FL
page

/ 4

Loading...
3b293b3febe32b0f77a618d8c8ac01c71f90 page 1
PSN-230/640/30/KNX REG
Code
90214 90214
90214
90214
DE
Sicherheitshinweise
EN
Safety instructions
FR
Consignes de sécurité
NL
Veiligheidsinstructies
Arbeiten an elektrischen Anlagen
dürfen nur von Elektrofachkräften
oder von unterwiesenen Personen
unter Leitung und Aufsicht einer
Elektrofachkraft entsprechend
den
elektrotechnischen Regeln
vorge nommen werden.
Work on the mains supply may
only be carried out by qualified
professionals or by instructed
persons under the direction and
supervision of qualified skilled
electrical personnel in accordance
with electrotechnical regulations.
Travailler sur un réseau
ne
s’improvise pas, seul un elec-
tricien qualifié et habilité doit
effectuer ce raccordement.
Werkzaamheden aan
elektrische installaties mogen
alleen door gekwalificeerde
installateurs of geschoold
personeel worden uitgevoerd
en dit in overeenstemming met
de elektrotechnische
voorschriften.
Vor Montage Leitung spannungs-
frei schalten!
Disconnect supply before
installing!
Avant de commencer l’ins-
tallation, assurez-vous que
l’alimentation est coupée.
Netspanning uitschakelen alvorens
te beginnen met de montage.
Beachten Sie die länder-
spezifischen Vorschriften sowie
die gültigen KNX-Richtlinien.
Observe the country-specific
regulations as well as the valid
KNX guidelines.
Respecter les réglementations
spécifiques du pays et les
directives KNX en vigueur.
Let op de landspecifieke
voorschriften en de geldende
KNX-richtlijnen.
Lesen Sie dieses Beiblatt vor
Inbetriebnahme des Gerätes.
Die Kenntnis dieses Beiblatts
gehört zur bestimmungsgemäßen
Verwendung des Gerätes!
Read this supplementary sheet
before putting the device
into operation. Knowledge of
this supplement is part of the
intended use!
Avant la mise en service de
l‘appareil, veuillez lire cette  che
complémentaire. La connaissance
de ce supplément fait partie de
l‘utilisation prévue de l‘appareil !
Lees dit aanvullende blad
voordat u het apparaat in gebruik
neemt. Kennis van dit document
maakt deel uit van het beoogde
gebruik.
Funktionsweise Operation Fonctionnement Werking
Das PSN-230/640/30/KNX REG
ist ein 640 mA KNX Netzteil mit
hohem Wirkungsgrad und mit
geringen Abmessungen von nur
3TE (52,5 mm).
The PSN-230/640/30/KNX REG
is a 640 mA KNX power supply
with high ef ciency and small
dimensions of only 52.5 mm.
Le PSN-230/640/30/KNX REG
est un bloc d’alimentation KNX
de 640 mA avec un rende-
ment élevé et des dimensions
réduites de seulement 52,5 mm.
De PSN-230/640/30/KNX REG
is een 640 mA KNX-voeding met
een hoog rendement en met
slechts een afmeting van 3TE
(52,5 mm).
Das Gerät verfügt über einen
KNX-Bus-Ausgang und einen
zusätzlichen Ausgang für Hilfs-
spannung (30 V DC).
Der große Temperaturbereich
von -5°C bis +50°C kann alle Arten
von Anwendungen abdecken.
Normalbetrieb, Überlastbedingun-
gen und RESET-Betrieb werden
über die eingebaute LED-Anzeige
angezeigt.
The device has a KNX bus output
and an additional output for
auxiliary power
(30 V DC)
.
The wide temperature operating
range from -5°C to +50°C can
meet all kinds of applications.
Integrated LED are used for
indication of normal operation,
overload conditions and RESET
operation.
L’appareil dispose d’une sortie
bus KNX et d’une sortie supplé-
mentaire pour tension auxiliaire
(30 V DC)
.
La plage de température de
-5°C à +50°C permet de couvrir
tous types d’applications. Le
fonctionnement normal, les
conditions de surcharge et le
fonctionnement RESET sont
indiqués par l’af chage LED
intégré.
Het apparaat heeft een KNX-bus-
uitgang en een extra uitgang
voor hulpspanning (30V DC).
Het brede temperatuurbereik
van -5°C tot +50°C is geschikt
voor allerlei toepassingen.
Normaal gebruik, overbelasting
en RESET-gebruik worden aange-
geven door het ingebouwde
LED-display.
90214

Chat with your B.E.G. PSN-230/640/30 KNX REG manual using AI

Get instant AI answers from your B.E.G. PSN-230/640/30 KNX REG manual

Ask anything about the B.E.G. PSN-230/640/30 KNX REG. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend PSN-230/640/30 KNX REG?

Yes No

Frequently Asked Questions

A

The maximum number of connected bus participants is 64. This limitation applies to the standard KNX bus capacity.

Is this answer helpful?

A

No, the device does not require configuration with the ETS tool. Setup is automatic upon correct wiring.

Is this answer helpful?

A

Press the reset button for at least 20 seconds to reset the KNX power supply effectively.

Is this answer helpful?

A

Yes, it includes protection against short circuits and overload to safeguard the system.

Is this answer helpful?

A

The unit is 3TE wide, measuring 90x52.5x58 mm, designed for DIN rail mounting.

Is this answer helpful?

A

Work may only be carried out by qualified professionals in accordance with electrotechnical regulations.

Is this answer helpful?

A

Solid wire 0.5 to 4.0 mm2 and stranded 0.5 to 2.5 mm2 fit the terminals properly.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Compact 3TE (52.5mm) design fits easily in electrical cabinets
  • High efficiency operation significantly reduces energy consumption
  • No ETS software configuration required for initial setup
  • Integrated LED indicators simplify fault diagnosis quickly
  • Provides separate 30V auxiliary output for external devices
VS

Disadvantages

  • Maximum support is limited to 64 KNX devices on the bus
  • Mains power must be disconnected by qualified personnel only
  • Backup time is very short at 200 ms during power loss
  • Operating temperature range is limited to negative 5 to 50 C
  • Wire strip length must be exact for proper terminal grip
M: QW-35-FL

Product Specification

Type

Power Supply

Standard

KNX

Function

Power Supply

Topology

Bus

Dimensions

3.54x2.07x2.28in

Features

IP20

M: QW-35-FL

Product Description

Overview of the B.E.G. PSN-230/640/30 KNX REG Power Supply

Integrating intelligent building systems requires reliable hardware that supports seamless communication. The B.E.G. PSN-230/640/30 KNX REG Power Supply 30V 3TE serves as a foundational component for these networks. It ensures stable power delivery to KNX bus lines while providing additional utility through its auxiliary voltage capability.

Compact Engineering

One of the primary advantages of this unit is its slim profile. With a width of only 3TE, measuring 52.5 mm, it integrates neatly into standard control cabinets. This space-saving design allows for efficient use of enclosure real estate. Despite the reduced size, it maintains a high efficiency rate, minimizing energy wastage. This feature is particularly beneficial for large installations aiming to reduce operational costs and heat generation.

Ease of Setup

Modern installations demand quick deployment times. This power supply simplifies the process significantly because it requires no configuration via external engineering software like ETS. Once you complete the wiring correctly, the system recognizes itself automatically. Visual feedback is provided through built-in LEDs that indicate operational status, reset events, or potential faults. Technicians can identify issues such as overloads instantly, speeding up troubleshooting procedures.

Robust Performance

The device operates reliably within a broad temperature range spanning from -5 degrees to +50 degrees Celsius. This flexibility accommodates diverse environments including server rooms, outdoor junction boxes, or climate-controlled offices. Protection mechanisms guard against short circuits and overvoltage events, enhancing longevity. Although it offers a short backup duration of 200 ms during mains failure, this brief buffer stabilizes the bus during momentary flickers. Users must adhere to maximum line lengths and participant counts to maintain signal integrity throughout the network.

Installation Considerations

Qualified electrical personnel should handle all installation tasks to ensure safety compliance. Before connecting any cables, the mains supply must be completely disconnected. Proper tools are essential to achieve the recommended tightening torque of 0.78 Newton meters. Selecting the correct wire type, either solid or stranded within specified millimeter gauges, ensures secure electrical contacts. Adhering to these guidelines minimizes risks and extends the lifespan of the entire KNX infrastructure. Ultimately, this power supply balances compactness with professional-grade reliability for demanding automation projects.

M: QW-35-FL

© Copyright 2026 Manual.ly