B.E.G. PD11-KNXs-FLAT-ST-DE Manual

0.0 · 0 Ratings

PDF manual · 16 Pages

English

M: QW-35-FL
page

/ 16

Loading...
bde7acfe040f9d8e076ebeb3d3cdd26aca4e page 4
93522
DE
Fehlersuche
UK
Trouble shooting
FR
Dépannages
NL
Foutopsporing
1. Die angeschlossene Leuchte
schaltet nicht
• Die Linse des Sensorteils ist
beschmutzt:
Linse reinigen
1. Luminaire does not light up
• Lens of sensor unit obstructed
by dirt or other objects:
Clean lens
1. Le luminaire ne s’allume pas
• La lentille du détecteur est
encrassée :
Nettoyer la lentille
1. De lamp schakelt niet
• Lens van de melder is vuil:
Lens reinigen.
2. Die angeschlossene Leuchte
schaltet zu spät ein oder die
Reichweite ist zu klein
• Der Melder ist zu hoch
montiert:
Gegebenenfalls Befesti-
gungshöhe korrigieren.
2. Luminaire turns ON too late or
detection range too small
• The detector is mounted
too high:
Correct mounting if required.
2. La source de lumière raccordée
s’allume trop tard ou la portée
est trop faible
• Le détecteur est installé à une
trop grande hauteur :
Si nécessaire, corriger la
hauteur de montage.
2. Het aangesloten licht schakelt
te laat in
• De melder is op te grote hoogte
geïnstalleerd:
Indien nodig, installatiehoogte
corrigeren.
3. Die Leuchte bleibt dauernd
eingeschaltet
• Permanente Wärmebewegun-
gen im Erfassungsbereich:
Wärmequelle entfernen. Den
korrekten Betrieb des Melders
durch Abdecken der Linse
kontrollieren. Nach Ablauf
der eingestellten Nachlaufzeit
muss der Melder das Licht
ausschalten.
3. Luminaire stays ON
continuously
• Continuous thermal activity
detected within detection
area:
Remove heat source. Check
proper function of the detector
by covering the lens. After
expiry of the follow-up time,
the detector has to turn OFF
lighting.
3. La lumière raccordée reste
allumée en permanence
• Perturbations infrarouges
permanentes dans la plage de
détection :
Eliminer la source de chaleur.
Contrôler le bon fonctionne
-
ment du détecteur en couvrant
la lentille. Après écoulement
de la temporisation réglée
le détecteur doit éteindre la
lumière.
3. Het aangesloten licht blijft
permanent ingeschakeld
• Storingsbron binnen het
detectiebereik:
Storingsbron verwijderen. De
correcte werking van de melder
controleren door de lens af te
dekken. Nadat de ingestelde
nalooptijd verstreken is, moet
de melder het licht uitscha-
kelen.
4. Ungewolltes Einschalten des
Lichtes
• Bewegungen von Wärmequel-
len im Erfassungsbereich:
-
Melder nicht in der Nähe
von Heizkörpern und Lüftern
montieren.
- Auch Tiere können vom Mel
-
der als sich bewegende Wär-
mequellen erfasst werden.
• Leuchten befinden sich im
direkten Erfassungsbereich.
Wärmequelle entfernen. Den
korrekten Betrieb des Melders
durch Abdecken der Linse
kontrollieren.
4. Unintended switching of light
• Movement of heat sources
within detection area:
- Do not install the detector in
the vicinity of radiators, fans
or air vents.
- Animals are detected as
moving heat sources, too.
• Lights are directly located in
the detection area.
Remove heat source. Check
proper function of the detector
by covering the lens.
4. Enclenchement intempestif de
la lumière
• Mouvements de source(s)
de chaleur dans la plage de
détection:
- Ne pas monter le détecteur
à proximité de radiateurs et
ventilateurs.
- Les animaux peuvent éga
-
lement être détectés par le
détecteur comme sources de
chaleur.
• Les éclairages sont directe-
ment dans le champ de vision
du détecteur.
Eliminer la source de chaleur.
Contrôler le bon fonctionne-
ment du détecteur en couvrant
la lentille.
4. Ongewild inschakelen van
het licht
• Bewegingen van warmtebron-
nen binnen het detectiebereik:
- Installeer de melder niet in de
buurt van radiatoren, airco
systemen of ventilators.
- Dieren worden ook als een
bewegende warmtebron
gedetecteerd.
• Verlichting bevindt zich direct
in de detectiezone.
Storingsbron verwijderen. De
correcte werking van de melder
controleren door de lens af te
dekken.
Produktseite im Internet Product page on the internet
Page produit sur notre site internet
Productpagina op het internet
Subject to technical changes 93522M1_Short_MAN_PD11-KNXs-ST-DE_93522_de_uk_fr_nl_V2 – 151222
92123 93067 B.E.G. One App
Brück Electronic GmbH I Gerberstr. 33 I 51789 Lindlar I GERMANY I Phone: +49 (0) 2266 90121-0 I [email protected] I beg-luxomat.com

Chat with your B.E.G. PD11-KNXs-FLAT-ST-DE manual using AI

Get instant AI answers from your B.E.G. PD11-KNXs-FLAT-ST-DE manual

Ask anything about the B.E.G. PD11-KNXs-FLAT-ST-DE. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend PD11-KNXs-FLAT-ST-DE?

Yes No

Frequently Asked Questions

A

The device uses a combination of motion detection and ambient light measurement. If there is movement and the surrounding brightness is below a configured threshold, the lighting activates. If enough light exists, it remains off to save energy.

Is this answer helpful?

A

The ideal mounting height is between two and five meters. For best performance, a height of approximately 2.5 meters is typically recommended to maximize the detection coverage angle.

Is this answer helpful?

A

Yes, the unit is capable of operating with KNX-Secure to prevent unauthorized system access. This function can be deactivated within the ETS software if required for specific projects.

Is this answer helpful?

A

Check for continuous thermal activity like heaters or moving animals within the range. Remove the heat source and ensure the lens is clean. The light should turn off after the programmed follow-up time expires.

Is this answer helpful?

A

Yes. Work on electrical systems must be conducted by qualified personnel. The device is not intended to isolate other equipment from the mains supply and requires proper wiring.

Is this answer helpful?

A

Yes, after connecting power, the unit enters a sixty-second self-test cycle to verify internal components. LEDs indicate the status during programming or motion detection phases.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Seamless KNX integration for smart building control systems and automation.
  • Integrated light sensor optimizes energy saving by reacting to daylight levels.
  • Compact design fits unobtrusively in various ceiling mounting configurations.
  • Self-test cycle ensures immediate fault detection upon power connection.
  • Adjustable detection range using supplied blinds prevents unwanted activation.
VS

Disadvantages

  • Installation strictly requires qualified electrical professionals due to voltage risks.
  • Indoor ceiling mounting limits deployment to specific architectural setups.
  • Potential false triggers if located near heat sources like radiators.
  • Requires ETS software configuration for advanced setting customization.
  • Sensitive lens may require regular cleaning to maintain accuracy.
M: QW-35-FL

Product Specification

Type

Motion Detector

Sensors

Infrared

Standard

KNX

Coverage Area

678.13 sq ft

Detection Angle

360 deg

Power Supply

Mains (230V)

Operating Temperature

14 deg F to 131 deg F

Dimensions

Dia 2.05 x 1.89 in

Weight

0.33 lbs

Protection Rating

IP54, IK10

M: QW-35-FL

Product Description

Enhancing Energy Efficiency with Smart Detection Technology

Modern building management systems rely heavily on intelligent components to reduce consumption while maintaining comfort for occupants. The B.E.G. PD11-KNXs-FLAT-ST-DE Presence Detector serves as a critical component in these networks. It is designed specifically for ceiling mounting in interior spaces where automated lighting control is essential. By integrating seamlessly into KNX bus systems, this device offers a robust solution for both commercial and residential environments requiring precise motion sensing.

The core functionality revolves around automatic switching based on two main inputs: the presence of individuals and the current ambient light levels. An integrated light sensor continuously monitors the environment. If natural light is sufficient, the system prevents unnecessary power usage by keeping the relay inactive. Conversely, when brightness drops below a specific set threshold, human movement triggers illumination immediately. This dual-input logic ensures optimal energy savings without sacrificing visibility or user convenience. Users can adjust settings via ETS software to tailor sensitivity and timing to their specific room layout.

Mounting requires careful consideration to ensure peak performance over the long term. The manufacturer recommends a height between two meters and five meters, with approximately two and a half meters often serving as an ideal baseline for best results. To prevent blind spots or missed detections, the main direction of movement should remain tangential to the unit rather than directly overhead. This positioning maximizes the three hundred sixty-degree circular detection area available to the sensor. Additionally, users can adjust the effective range using enclosed blinds if large areas require exclusion zones or interference reduction.

Safety standards are paramount during operation and daily maintenance. Only qualified electrical personnel should perform installation tasks involving mains connections. The device must never be used as an isolation switch for other equipment connected to the supply. Upon initial power connection, the unit undergoes a sixty-second self-test cycle to verify internal components and sensors are functioning correctly. Visual feedback is provided through distinct LED indicators signaling motion detection or programming modes for ease of commissioning.

Security protocols have been updated to meet modern threats within smart buildings. The product supports KNX Secure functionality, which protects against unauthorized access to the system via the transmission path. Configuration details such as the FDSK key are printed directly on the hardware or available as QR codes for verification. Compliance with European directives regarding electromagnetic compatibility and low voltage further guarantees reliability in regulated markets.

Troubleshooting and Maintenance

Regular checks help maintain system integrity. Clean the lens regularly if dust accumulation occurs. Ensure no radiators or fans are located directly within the detection circle.