Bachmann BlueNet BN0500 Manual

0.0 · 0 Ratings

PDF manual · 20 Pages

English

M: OA-GPT-54-NAN
page

/ 20

Loading...
4f864a2769b910097e73b8803191a1076500 page 8
8
bachmann.com
english
BlueNet BN0500
Thank you
Congratulations on selecting the intelligent BN0500 power strip from Bachmann's BlueNet series. From the
moment of installation, the various products in the Bachmann BlueNet range will deliver you a high level of cost-
effectiveness. The various modules offer you the best conditions for setting up an optimized energy management
system.
Before starting to use this product please read the entire manual and observe all operational and safety notices
to ensure safe operation.
Safety Information
Use only in indoor, well ventilated and dry areas.
Never use the power strip immediately after bringing it into a warm room from a cold one.
The condensation this creates can, in some cases, cause a shortcircuit and destroy the product.
It also presents a fatal electrocution hazard!
The power cable of the power strip must be neither repaired nor replaced. If the power cable is damaged, the
power strip must be replaced.
Ensure when selecting the installation site that no high humidity, high temperatures (see Technical Data),
moisture, solvents, ammable gases, dust or vapors are present. The heat generated during operation must
be dissipated.
The power strip may be operated only when connected to power socket protected by a 16A fuse. Do not ex-
ceed the maximum power transmission (see Technical Data). If the power strip shows outward signs of wear
from transport or improper handling, it must not be put into operation or must be put out of operation immedi-
ately and must be replaced or sent back to the manufacturer for repair.
Danger of fatal electric shock:
Never carry out work on the power strip with wet hands.
Risk of nger crushing during installation or mounting work.
BlueNet BN0500 is a maintenance-free system.
There is no need to open the housing during installation.
Do not use aggressive substances such as spirits or acids to clean the unit, as these can damage it.
To clean the housing use a slightly moistened cloth.
Observing these notices is part of our terms of warranty.
The product fullls the requirements of the valid European and national directives and standards.
The CE conformity has been documented, and the corresponding certicates are on le at the
manufacturer's location.

Chat with your Bachmann BlueNet BN0500 manual using AI

Get instant AI answers from your Bachmann BlueNet BN0500 manual

Ask anything about the Bachmann BlueNet BN0500. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend BlueNet BN0500?

Yes No

Frequently Asked Questions

A

It is used to distribute power to multiple devices in a rack or cabinet while also showing key electrical values for monitoring and energy control.

Is this answer helpful?

A

It provides 8 Schuko outlets, making it suitable for connecting several IT or electrical devices in a compact 1U form factor.

Is this answer helpful?

A

Yes. It displays and stores kWh usage, along with voltage, current, active power, frequency, and phase angle for ongoing supervision.

Is this answer helpful?

A

Yes. The kWh counter can be reset using the front button. The stored reading is retained and can be cleared during normal operation.

Is this answer helpful?

A

When the load reaches 90% of rated capacity, the display flashes as an alarm. This warning remains active until it is acknowledged.

Is this answer helpful?

A

No. It is intended for indoor, dry, well-ventilated spaces only. Moisture, condensation, and harsh environments should be avoided.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • 8 Schuko outlets in a compact 1U format save rack space.
  • Live readings help monitor voltage, current, power, frequency, and energy.
  • 90% overload warning adds an extra layer of operational safety.
  • Mounting brackets support multiple installation positions for flexibility.
VS

Disadvantages

  • Designed for indoor, dry environments only, so use is limited.
  • The fixed power cable cannot be repaired or replaced.
  • No advanced networking or remote control features are described.
  • Mounting hardware is not included, which may add installation prep.
M: OA-GPT-54-NAN

Product Specification

Outputs

8x Schuko

Input

1x Schuko

Input voltage

230V

Power

3600W (max.)

Additional connections

N/A

Material

Aluminum

Cable length

78.74in

Dimensions (WxHxD)

19.02x1.77x1.85in

Special features

rack-mountable, 35-degree arrangement, Display

M: OA-GPT-54-NAN

Product Description

Bachmann 19" IT PDU BlueNet BN0500, 8x Schuko, 1U, 2m Manual

The Bachmann 19" IT PDU BlueNet BN0500 is a practical choice for rack-based environments that need dependable power distribution and transparent energy monitoring. Built for cabinet installation, this 1U power strip combines eight Schuko outlets with a 2 m supply cable, making it a compact fit for server rooms, network racks, and professional IT setups.

What makes the BlueNet BN0500 especially interesting is its focus on visibility. Instead of acting as a simple multi-socket strip, it continuously displays key electrical values such as voltage, current, active power, energy consumption, frequency, and phase angle. That makes it easier to understand how equipment is performing and to spot changes in load before they become a problem. For teams managing multiple devices, this is a useful step toward smarter energy control.

Installation is designed with flexibility in mind. The included mounting brackets can be fitted in four positions, allowing the unit to adapt to different rack layouts. Once mounted, the display can be activated with a button, and the built-in energy counter can be reset when needed. The stored kWh reading remains available even after power is disconnected, which is ideal for ongoing tracking and reporting.

The BN0500 also adds a useful safety feature: a near-overload alarm. When the load reaches 90% of rated capacity, the display begins to flash, giving an early warning before the system is pushed too far. Combined with the product’s maintenance-free design and clear operating logic, this makes it a reliable addition to structured IT infrastructure.

For day-to-day use, the PDU is intended for indoor, dry, well-ventilated environments only. That fits typical data cabinet conditions and reinforces its role as a serious infrastructure component rather than a general-purpose household accessory. In short, the Bachmann BlueNet BN0500 is a compact, monitor-friendly PDU that balances usability, safety, and control.

Notes

  • Best suited for rack cabinets and controlled technical spaces.
  • Ideal when energy visibility matters as much as power delivery.
  • Follow load limits and installation guidance for safe operation.
M: OA-GPT-54-NAN