Operation Instructions
Safety advice:
4
Installation and repairs to the equipment may only be carried out by
technicians observing the current VDE guidelines. No liability will be assumed
in the case of faulty installation and commissioning.
4
Before opening the equipment pull out the power plug or remove the power
supply, otherwise there is danger of electrocution. This is also valid for cleaning
the equipment or working on the connections.
4
Only use the mains cable connected to the device. Never replace any parts or
make any modifications on the mains cable. Otherwise there is a risk of mortal
injury for which we cannot be held liable.
4
Providing that a serviceable fuse exists, the power plug must be pulled out
before changing the fuse. Defective fuses may only be replaced with standard
compliant fuses that have the same nominal value.
4
The equipment may only be operated in dry rooms. In humid rooms or
outdoors there is danger of short-circuit (caution: risk of fire) or electrocution.
4
To prevent damage to your equipment and to avoid possible peripheral
damages, the devices foreseen for wall mounting may only be installed on a
flat surface.
4
Choose the location of installation or mounting so that the power plug can be
reached and pulled out of the socket easily in case of danger. Choose the
location of installation or mounting such that children may not play
unsupervised near the equipment and its connections. The location of
installation or mounting must allow a safe installation of all cables connected.
The mains cable as well as feeder lines may not be damaged or clamped by
objects of any kind.
4
Choose the location of installation or mounting so that under no circumstances
liquids or objects can get into the equipment (e.g. condensation, water coming
from leaking roofs or flowing water, etc.).
4
Avoid exposure of the equipment to direct sunlight and to other heat sources
(e. g. radiators. other electrical devices, chimney, etc.). Devices that are
equipped with heat sinks or ventilation slots must under no circum-stances be
covered or blocked. Also ensure for a generous air circulation around the
equipment. In this way you avoid possible damage to the equipment as well as
a risk of fire caused by overheating. Absolutely avoid that cables come near
any source of heat (e.g. radioators, other electrical devices, chimney, etc.).
WEEE Nr.
DE14023300
Your device is marked with the WEEE symbol (Waste Electronics and
Electrical Equipment). This means that the electrical and electronic
components must not be disposed of as residual waste. Used electrical and
electronic components must be disposed of separately.
Technical specifications:
SPU 996-09 SPU 998-09 SPU 9912-09 SPU 9918-09 SPU 9918-19
Frequency range (return path | TERR | SAT) 5…65 MHz | 85…862 MHz | 950…2200 MHz
Number of inputs 9
Number of trunk outputs 9
Subscriber ports 6 8 12 18 18
Tap loss TERR 20 dB 22 dB 25 dB 28 dB 25…29 dB
Tap loss SAT passive 19…16 dB 21...18 dB –
Tap loss SAT active – 6...3 dB
Output level SAT receiver SAT
1
– 98 dBµV
Current consumption per Subscriber port 25 mA 55 mA
Through loss TERR 5 dB 6 dB 7 dB
Through loss SAT 2...5 dB 3...6 dB 3...7 dB 3...7 dB
Switching isolation >26 dB
Isolation trunk lines >30 dB
Isolation of outputs >26 dB
Selection (SAT | TERR) >40 dB
Connectors F
Ambient temperature range (acc. to EN 60065) -20…+50°C
Dimensions (W × H × D) appr. 230 × 125 × 40 mm 230 × 145 × 40 mm 230 × 180 × 40 mm 230 × 255 × 40 mm 230 × 255 × 40 mm
1
3rd order SAT EN 50083-3@35dB IMA

Chat with your Axing SPU 9912-09 manual using AI

Get instant AI answers from your Axing SPU 9912-09 manual

Ask anything about the Axing SPU 9912-09. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend SPU 9912-09?

Yes No

Frequently Asked Questions

A

It is used to distribute satellite IF polarization levels and terrestrial signals to multiple receivers in a home RF system. It helps organize multi-room signal delivery with cascade flexibility.

Is this answer helpful?

A

The SPU 9912-09 supports up to 12 subscriber ports, so it is a practical choice for medium-sized residential installations.

Is this answer helpful?

A

Yes. Along with satellite signals, it can distribute terrestrial signals such as FM radio, which makes it more versatile in home installations.

Is this answer helpful?

A

A compatible multiswitch or head amplifier may be required, along with F/F Quickfix adapters, high-shield coaxial cables, and termination resistors for the final outputs.

Is this answer helpful?

A

No. The unit is intended for dry indoor rooms only. Moisture, humidity, and outdoor exposure can cause short circuits or other damage.

Is this answer helpful?

A

Proper grounding supports safety, helps protect connected equipment, and aligns the installation with the required electrical standards.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • Supports up to 12 subscriber ports, making it suitable for medium-sized multi-room installations.
  • Combines satellite IF and terrestrial signals in one cascade system for simpler distribution.
  • Strong isolation and selection help preserve signal quality across the network.
  • Compact design makes it easier to mount in limited spaces.
  • Can be expanded in a cascaded setup for larger installations.
VS

Disadvantages

  • Requires professional installation and careful attention to safety rules.
  • Intended for dry indoor environments only, not for outdoor use.
  • Larger systems may need extra multiswitches or amplification.
  • Cabling, termination, and grounding must be done precisely.
  • Not suitable for uses outside home RF signal distribution.
M: OA-GPT-54-NAN

Product Specification

Satellite Inputs

8

Terrestrial Inputs

1

Outputs

12, 8 (Sat-Loop), 1 (Terrestrial-Loop)

Cascadable

yes

Satellite Positions

2

Dimensions

9.06x7.09x1.57in (WxHxD)

M: OA-GPT-54-NAN

Product Description

Axing SPU 9912-09 Manual: Practical Cascade Distribution for Home Satellite Systems

The Axing SPU 9912-09 is designed for one clear purpose: to help distribute satellite and terrestrial signals neatly across a home installation. In the context of the Axing SPU 9912-09 Manual, the unit stands out as a cascade module built for structured RF networks where signal quality, isolation, and expansion matter. It supports 8 satellite IF polarization levels plus terrestrial signals, making it a useful component for multi-room TV setups.

One of the most appealing aspects of this premium-line device is its scalability. The SPU 9912-09 supports up to 12 subscriber ports, which makes it a strong fit for medium-sized homes or residential systems that need more than a simple splitter. The cascade design allows multiple units to be chained, so installers can expand the system while keeping the signal path organized. For users planning a future upgrade, this flexibility is a real advantage.

The technical profile also reflects a focus on stable distribution. With nine inputs, nine trunk outputs, and strong isolation values, the unit is built to keep signals separated and manageable across the network. The manual emphasizes correct cabling, termination, and grounding, which is important because this device is intended for professional RF installations rather than quick DIY work. High-shield coaxial cables, proper F connectors, and clean termination at the end of the chain all help preserve performance.

Another practical benefit is the combination of satellite and terrestrial handling in one compact unit. That means FM radio or other terrestrial signals can travel alongside the satellite feeds without requiring a separate distribution path. For installers, this simplifies planning and can reduce clutter in the equipment area. The compact form factor also helps when space is limited, especially in racks or wall-mounted setups.

Installation Notes

The SPU 9912-09 should only be used indoors in dry rooms and installed by a qualified technician. Following the grounding guidance and leaving ventilation space around the unit helps protect both the hardware and the overall system. When several cascade units are used, the system may require additional amplification to balance loss across the chain.

Quick Takeaway

The Axing SPU 9912-09 Manual points to a reliable cascade solution for organized signal distribution, especially where expandability and signal integrity are top priorities. It is best suited for users who want a professional-grade, future-ready satellite distribution setup.

  • Use proper termination on the final outputs.
  • Keep the unit away from moisture and heat.
  • Follow grounding and safety rules carefully.
M: OA-GPT-54-NAN

© Copyright 2026 Manual.ly