Axing SPU 98-06 Manual

0.0 · 0 Ratings

PDF manual · 4 Pages

English

M: OA-GPT-54-NAN
page

/ 4

Loading...
a9f403cf136681d79e798bac67bd7c730418 page 3
Manufacturer
AXING AG
Gewerbehaus Moskau
8262 Ramsen
EWR contact adress
Bechler GmbH
Am Rebberg 44
78239 Rielasingen
State of the art 2017-09-12
Technical changes, design modifications, errors and misprints are subject to
change without prior notice.
Safety advices:
Installation and repairs to the equipment may only be carried out by
technicians observing the current VDE guidelines. No liability will be
assumed in the case of faulty installation and commissioning.
Before opening the equipment pull out the power plug or remove the
power supply, otherwise there is danger of electrocution. This is also
valid for cleaning the equipment or working on the connections.
Only use the mains cable connected to the device. Never replace any
parts or make any modifications on the mains cable. Otherwise there is a
risk of mortal injury for which we cannot be held liable.
Providing that a serviceable fuse exists, the power plug must be pulled
out before changing the fuse. Defective fuses may only be replaced with
standard compliant fuses that have the same nominal value.
The equipment may only be operated in dry rooms. In humid rooms or
outdoors there is danger of short-circuit (caution: risk of fire) or
electrocution.
To prevent damage to your equipment and to avoid possible peripheral
damages, the devices foreseen for wall mounting may only be installed
on a flat surface.
Choose the location of installation or mounting so that the power plug
can be reached and pulled out of the socket easily in case of danger.
Choose the location of installation or mounting such that children may
not play unsupervised near the equipment and its connections. The
location of installation or mounting must allow a safe installation of all
cables connected. The mains cable as well as feeder lines may not be
damaged or clamped by objects of any kind.
Choose the location of installation or mounting so that under no
circumstances liquids or objects can get into the equipment (e.g.
condensation, water coming from leaking roofs or flowing water, etc.).
Avoid exposure of the equipment to direct sunlight and to other heat
sources (e. g. radiators. other electrical devices, chimney, etc.). Devices
that are equipped with heat sinks or ventilation slots must under no
circum-stances be covered or blocked. Also ensure for a generous air
circulation around the equipment. In this way you avoid possible damage
to the equipment as well as a risk of fire caused by overheating.
Absolutely avoid that cables come near any source of heat (e.g.
radioators, other electrical devices, chimney, etc.).
SPU 98-06 | SPU 912-06
SPU 916-06 | SPU 924-06
SPU 932-06
basic-line
Multiswitches /
Cascade units
Operation instructions
Technical data:
Your device is marked with the WEEE symbol (Waste Electronics and
Electrical Equipment). This means that the electrical and electronic
components must not be disposed of as residual waste. Used electrical and
electronic components must be disposed of separately.
WEEE Nr.
DE26869279
Article SPU 98-06 SPU 912-06 SPU 916-06 SPU 924-06 SPU 932-06
Frequency range (TERR | SAT) 5…862 MHz | 950…2400 MHz
Number of inputs 9
Number of trunk outputs 9
Subscriber ports 8 12 16 24 32
Tap loss TERR 24 dB ±2 dB 28 dB ±3 dB 32 dB ±3 dB
Tap loss SAT 2…0 dB ±2 dB 2…1 dB ±2 dB 2…0 dB ±2 dB
Max. output level subscriber ports SAT
1
102 dBµV
Switch commands 13/18 V, 0/22 kHz, DiSEqC 1.0
Through loss TERR 2…3dB ±1,5 dB 4…5 dB ±1,5 dB 4…6 dB ±1 dB
Through loss SAT 1…2 dB ±1,5dB 1,5…3 dB ±1,5 dB 2...6 dB ±1,5 dB
Isolation V®H. >30 dB
Isolation TERR input®SAT. input 30 dB
Ambient temperature range (acc. to EN 60065) -20…+50°C
Current consumption per subscriber port
(withoutLNB supply)
<45 mA
Max. LNB supply current 1500 mA
Stromaufnahme vom Netzteil 10 mA
Potentialausgleichanschluss 4 mm2
Maße (B × H × T) ca. 128 x 202 x 63 mm 189 x 202 x 63 mm 306 x 202 x 63 mm
Schutzklasse IP 20
1
3rd order SAT max. EN50083-3 35dB KMA (2 Sender Messmethode)

Chat with your Axing SPU 98-06 manual using AI

Get instant AI answers from your Axing SPU 98-06 manual

Ask anything about the Axing SPU 98-06. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend SPU 98-06?

Yes No

Frequently Asked Questions

A

It is used to distribute satellite and terrestrial RF signals inside a building. It helps connect one reception system to multiple subscriber outlets while keeping signal handling organized and reliable.

Is this answer helpful?

A

Yes. The unit can be expanded with cascade units, which makes it suitable for larger installations. The outputs of the multiswitch are connected to the inputs of the cascade units for system growth.

Is this answer helpful?

A

Yes. The device requires an SZU 99-06 power supply, which is not included. The power supply is connected to the DC socket and then plugged into a mains outlet.

Is this answer helpful?

A

No. It is intended for dry indoor rooms only. Humid locations or outdoor use can create risks such as short circuits, fire, or electric shock.

Is this answer helpful?

A

It supports terrestrial signals from 5 to 862 MHz and satellite signals from 950 to 2400 MHz. It is designed to work with standard SAT control methods like 13/18 V, 0/22 kHz, and DiSEqC 1.0.

Is this answer helpful?

A

Yes. If cascade units are not connected, the unused lower outputs should be terminated with CFA 11-00 resistors. This helps maintain proper signal behavior in the system.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • Combines SAT and terrestrial signal distribution in one device.
  • Supports cascading, making larger installations easier to expand.
  • Compatible with DiSEqC 1.0 and standard SAT control signals.
  • Offers strong output performance and clear equipotential bonding support.
VS

Disadvantages

  • Installation and repairs should only be handled by qualified professionals.
  • A separate SZU 99-06 power supply is required.
  • Unused outputs need termination parts that are not included.
  • Designed for dry indoor use only, not for outdoor or humid areas.
M: OA-GPT-54-NAN

Product Specification

Satellite Inputs

8

Terrestrial Inputs

1

Outputs

8, 4 (Sat-Loop), 1 (Terrestrial-Loop)

Cascadable

yes

Satellite Positions

2

Dimensions

5.04x7.95x2.48in (WxHxD)

M: OA-GPT-54-NAN

Product Description

Axing SPU 98-06: Flexible Signal Distribution for Modern SAT Installations

The Axing SPU 98-06 is a compact multiswitch designed for reliable in-house distribution of satellite and terrestrial TV signals. It fits well into residential antenna systems where a clean, organized signal path matters, and it is especially useful when multiple viewing points need stable access to the same source. The Axing SPU 98-06 Manual makes it clear that the unit is built for practical everyday use, with support for both SAT and terrestrial input signals in a single solution.

One of the main strengths of this model is its ability to handle common SAT control commands such as 13/18 V, 0/22 kHz, and DiSEqC 1.0. That makes it compatible with a wide range of receivers and LNB setups. The device also supports terrestrial distribution, which is helpful for combining satellite television with radio or broadcast services like DAB+ in one installation. For users planning larger systems, cascading support adds extra flexibility and helps expand the network without starting from scratch.

The SPU 98-06 is part of AXING’s basic-line family, and it focuses on dependable performance rather than unnecessary complexity. With multiple subscriber outputs, strong isolation values, and a high maximum output level, it is designed to keep signal quality consistent across the installation. The housing and mounting design also reflect a professional approach, including potential equalization support and clear connection points for coaxial cabling.

Safety and installation are important themes throughout the product guidance. The unit is intended for dry indoor environments only, and installation should be carried out by qualified technicians. It should also be connected to equipotential bonding to reduce the risk of dangerous overvoltage. In practice, this makes the SPU 98-06 a solid choice for structured home distribution systems where reliability and safety are priorities.

If you are looking for a straightforward way to distribute SAT and terrestrial signals efficiently, the Axing SPU 98-06 offers a balanced mix of compatibility, expandability, and technical confidence. It is not just about connecting cables; it is about building a system that remains stable, serviceable, and ready for future extension.

Notes

  • Best suited for indoor antenna distribution systems
  • Requires a separate SZU 99-06 power supply
  • Unused outputs should be properly terminated
  • Professional installation is strongly recommended
M: OA-GPT-54-NAN