SPU 94-05 | SPU 96-05
SPU 98-05 | SPU 912-05
SPU 916-05
basic-line
Multiswitches
Operation Instructions
Safety advice:
4
Installation and repairs to the equipment may only be carried out by
technicians observing the current VDE guidelines. No liability will be
assumed in the case of faulty installation and commissioning.
4
Before opening the equipment pull out the power plug or remove the
power supply, otherwise there is danger of electrocution. This is also
valid for cleaning the equipment or working on the connections.
4
Only use the mains cable connected to the device. Never replace any
parts or make any modifications on the mains cable. Otherwise there is a
risk of mortal injury for which we cannot be held liable.
4
Providing that a serviceable fuse exists, the power plug must be pulled
out before changing the fuse. Defective fuses may only be replaced with
standard compliant fuses that have the same nominal value.
4
The equipment may only be operated in dry rooms. In humid rooms or
outdoors there is danger of short-circuit (caution: risk of fire) or
electrocution.
4
To prevent damage to your equipment and to avoid possible peripheral
damages, the devices foreseen for wall mounting may only be installed
on a flat surface.
4
Choose the location of installation or mounting so that the power plug
can be reached and pulled out of the socket easily in case of danger.
Choose the location of installation or mounting such that children may
not play unsupervised near the equipment and its connections. The
location of installation or mounting must allow a safe installation of all
cables connected. The mains cable as well as feeder lines may not be
damaged or clamped by objects of any kind.
4
Choose the location of installation or mounting so that under no
circumstances liquids or objects can get into the equipment (e.g.
condensation, water coming from leaking roofs or flowing water, etc.).
4
Avoid exposure of the equipment to direct sunlight and to other heat
sources (e. g. radiators. other electrical devices, chimney, etc.). Devices
that are equipped with heat sinks or ventilation slots must under no
circum-stances be covered or blocked. Also ensure for a generous air
circulation around the equipment. In this way you avoid possible
damage to the equipment as well as a risk of fire caused by overheating.
Absolutely avoid that cables come near any source of heat (e.g.
radioators, other electrical devices, chimney, etc.).
WEEE Nr.
DE14023300
Your device is marked with the WEEE symbol (Waste Electronics
and Electrical Equipment). This means that the electrical and
electronic components must not be disposed of as residual waste.
Used electrical and electronic components must be disposed of
separately.
Manufacturer
AXING AG
Gewerbehaus Moskau
8262 Ramsen
EWR contact adress
Bechler GmbH
Am Rebberg 44
78239 Rielasingen
State of the art 2016-07-20 Technical changes, design modifications,
errors and misprints are subject to change without prior notice

Chat with your Axing SPU 916-05 manual using AI

Get instant AI answers from your Axing SPU 916-05 manual

Ask anything about the Axing SPU 916-05. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend SPU 916-05?

Yes No

Frequently Asked Questions

A

It is used to distribute satellite signals and terrestrial signals to multiple rooms in a home. The multiswitch helps centralize signal routing from LNB and antenna sources to several subscriber outputs.

Is this answer helpful?

A

The SPU 916-05 provides 16 subscriber outputs, making it suitable for larger residential installations where multiple receivers or TV points need access to the same signal network.

Is this answer helpful?

A

Yes. It includes a terrestrial input for signals such as FM radio or terrestrial TV. This allows both satellite and antenna-based signals to be integrated in one distribution setup.

Is this answer helpful?

A

Yes, proper grounding is strongly recommended and is important for safety. Grounding helps reduce the risk of dangerous voltage surges and supports compliant installation practice.

Is this answer helpful?

A

It should be installed indoors in a dry room, on a flat surface, with enough ventilation and easy access to power. It should not be placed where moisture, direct sunlight, or heat sources can affect it.

Is this answer helpful?

A

Use highly shielded coaxial cables with F connectors. Good cable quality helps preserve signal integrity and reduces interference across the distribution network.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • Supports up to 16 subscriber outputs for larger home setups.
  • Combines satellite and terrestrial signal distribution in one unit.
  • Wide frequency coverage suits common SAT and broadcast use.
  • Low power draw helps keep the installation efficient.
VS

Disadvantages

  • Requires careful grounding and professional-style installation.
  • Not suitable for humid rooms or outdoor placement.
  • Needs high-quality coaxial cabling for best performance.
  • Installation is less beginner-friendly than a simple splitter.
M: OA-GPT-54-NAN

Product Specification

Satellite Inputs

8

Terrestrial Inputs

1

Outputs

16

Cascadable

no

Satellite Positions

2

Dimensions

19.02x4.92x3.15in (WxHxD)

M: OA-GPT-54-NAN

Product Description

Axing SPU 916-05 Manual: A Practical Look at a Powerful Home Multiswitch

The Axing SPU 916-05 is a compact multiswitch designed to simplify satellite signal distribution in a house. In everyday use, it helps route SAT signals to multiple rooms while also integrating terrestrial signals such as FM or TV antenna reception. For anyone searching for the Axing SPU 916-05 Manual, the main idea is simple: this unit is built for clean, centralized signal management with a focus on reliability, tidy cabling, and stable performance.

One of the standout features of the SPU 916-05 is its support for 16 subscriber connections, making it a strong choice for medium to larger residential installations. It accepts signals across the standard SAT range, includes a terrestrial input, and is intended for use with high-shielded coaxial cables and F connectors. This makes it well suited to structured home antenna networks where signal quality matters and every room needs dependable access.

The product also emphasizes safety and installation discipline. It must be grounded correctly, installed in dry indoor spaces, and connected with proper care to avoid overload, overheating, or electrical risk. That focus on safe setup is especially useful for installers and advanced users who want long-term stability. The SPU 916-05 is not meant for casual outdoor use or improvised mounting; it performs best when installed neatly on a flat surface with adequate ventilation and accessible power supply.

From a technical perspective, the device offers a broad frequency range and low power consumption, which supports efficient operation without adding much burden to the system. Its design reflects a balance between practical installation and dependable signal routing. If your goal is to distribute satellite and terrestrial signals throughout a home, the SPU 916-05 offers a straightforward and professional solution.

In short, the Axing SPU 916-05 is built for users who want a stable multiswitch with enough outputs for multiple rooms, clear grounding requirements, and solid integration of SAT and terrestrial feeds. It is a sensible choice for organized home distribution setups where performance and safety go hand in hand.

Notes

  • Best used in dry indoor environments only.
  • Proper grounding is essential for safe operation.
  • Use shielded coaxial cables with F connectors for best results.