Manufacturer
AXING AG
Gewerbehaus Moskau
8262 Ramsen
EWR contact adress
Bechler GmbH
Am Rebberg 44
78239 Rielasingen
State of the art 2017-09-12
Technical changes, design modifications, errors and misprints are subject to
change without prior notice.
Safety advices:
Installation and repairs to the equipment may only be carried out by
technicians observing the current VDE guidelines. No liability will be
assumed in the case of faulty installation and commissioning.
Before opening the equipment pull out the power plug or remove the
power supply, otherwise there is danger of electrocution. This is also
valid for cleaning the equipment or working on the connections.
Only use the mains cable connected to the device. Never replace any
parts or make any modifications on the mains cable. Otherwise there is a
risk of mortal injury for which we cannot be held liable.
Providing that a serviceable fuse exists, the power plug must be pulled
out before changing the fuse. Defective fuses may only be replaced with
standard compliant fuses that have the same nominal value.
The equipment may only be operated in dry rooms. In humid rooms or
outdoors there is danger of short-circuit (caution: risk of fire) or
electrocution.
To prevent damage to your equipment and to avoid possible peripheral
damages, the devices foreseen for wall mounting may only be installed
on a flat surface.
Choose the location of installation or mounting so that the power plug
can be reached and pulled out of the socket easily in case of danger.
Choose the location of installation or mounting such that children may
not play unsupervised near the equipment and its connections. The
location of installation or mounting must allow a safe installation of all
cables connected. The mains cable as well as feeder lines may not be
damaged or clamped by objects of any kind.
Choose the location of installation or mounting so that under no
circumstances liquids or objects can get into the equipment (e.g.
condensation, water coming from leaking roofs or flowing water, etc.).
Avoid exposure of the equipment to direct sunlight and to other heat
sources (e. g. radiators. other electrical devices, chimney, etc.). Devices
that are equipped with heat sinks or ventilation slots must under no
circum-stances be covered or blocked. Also ensure for a generous air
circulation around the equipment. In this way you avoid possible damage
to the equipment as well as a risk of fire caused by overheating.
Absolutely avoid that cables come near any source of heat (e.g.
radioators, other electrical devices, chimney, etc.).
SPU 58-06 | SPU 512-06
SPU 516-06 | SPU 524-06
SPU 532-06
basic-line
Multiswitches /
Cascade units
Operation instructions
Technical data:
Your device is marked with the WEEE symbol (Waste Electronics and
Electrical Equipment). This means that the electrical and electronic
components must not be disposed of as residual waste. Used electrical and
electronic components must be disposed of separately.
WEEE Nr.
DE26869279
Article SPU 58-06 SPU 512-06 SPU 516-06 SPU 524-06 SPU 532-06
Frequency range (TERR | SAT) 5…862 MHz | 950…2400 MHz
Number of inputs 5
Number of trunk outputs 5
Subscriber ports 8 12 16 24 32
Tap loss TERR 23 dB ±2 dB 27 dB ±3 dB 33 dB ±3 dB
Tap loss SAT -1...-3 dB ±2 dB -1...-2 dB ±2 dB 2...-1 dB ±2 dB
Max. output level subscriber ports SAT
1
102 dBµV
Switch commands 13/18 V, 0/22 kHz
Through loss TERR 2 dB ±1 dB 2…3 dB ±1 dB 2 dB ±2 dB
Through loss SAT 2 dB ±1 dB 2…4 dB ±1 dB 2…6 dB ±2 dB
Isolation V®H. >30 dB
Isolation TERR input®SAT. input 30 dB
Ambient temperature range (acc. to EN 60065) -20…+50°C
Current consumption per subscriber port
(withoutLNB supply)
< 35 mA
Max. LNB supply current 1500 mA
Equipotential bonding connection 4 mm2
Dimensions (W × H × D) appr. 112 x 137 x 63 mm 150 x 137 x 63 mm 240 x 137 x 63 mm
Protection class IP 20
1
3rd order SAT max. EN50083-3 35dB KMA (2 sender test method)

Chat with your Axing SPU 58-06 manual using AI

Get instant AI answers from your Axing SPU 58-06 manual

Ask anything about the Axing SPU 58-06. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend SPU 58-06?

Yes No

Frequently Asked Questions

A

It is used to distribute satellite and terrestrial signals to multiple rooms in a house. The unit supports structured indoor antenna setups and is suitable for compact residential installations.

Is this answer helpful?

A

The SPU 58-06 version supports 8 subscriber ports. Other variants in the same series offer more ports, but this model is designed for smaller distribution needs.

Is this answer helpful?

A

Yes. It is built for combined SAT and terrestrial use, so it can pass signals such as TV or radio alongside satellite IF distribution.

Is this answer helpful?

A

Yes. The system is designed for cascading, which allows installers to link additional units for larger multi-room setups. Unused outputs should be terminated properly.

Is this answer helpful?

A

An external power supply may be needed if the connected receivers do not provide enough voltage for the LNB and the distribution system. The SZU 99-06 is mentioned as a compatible option.

Is this answer helpful?

A

No. It is intended only for dry indoor rooms. Moisture, rain, or humid conditions can create safety risks and may damage the device.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • Supports both SAT and terrestrial signal distribution in one system.
  • Compact design suits small technical spaces and home installations.
  • Cascading support makes system expansion easier.
  • Receiver-powered operation can reduce the need for extra hardware.
VS

Disadvantages

  • Indoor dry-room use only; not suitable for outdoor or humid areas.
  • Proper grounding and termination are required for safe operation.
  • Some accessories and the external power supply are not included.
  • Subscriber capacity is limited compared with larger distribution systems.
M: OA-GPT-54-NAN

Product Specification

Satellite Inputs

4

Terrestrial Inputs

1

Outputs

8, 4 (Sat-Loop), 1 (Terrestrial-Loop)

Cascadable

yes

Satellite Positions

1

Dimensions

4.41x5.39x2.48 in (WxHxD)

M: OA-GPT-54-NAN

Product Description

Axing SPU 58-06: Compact Signal Distribution for SAT and Terrestrial Networks

The Axing SPU 58-06 is a practical solution for distributing satellite and terrestrial signals in a home installation. Built as part of the basic-line family, it is aimed at users who want a clean and reliable way to feed multiple rooms from one central setup. The unit combines SAT input handling, terrestrial signal passing, and subscriber distribution in a compact housing that fits well into structured indoor antenna systems.

What makes the SPU 58-06 interesting is its balance between simplicity and flexibility. It works with the standard control signals used in satellite reception, such as 13/18 V and 0/22 kHz, and supports a frequency range that covers both terrestrial TV and satellite reception. That means it can be used in systems where radio, DVB-T/T2, DAB+, or cable-like terrestrial signals need to travel alongside SAT IF signals. For many households, this creates a more unified and manageable setup.

The Axing SPU 58-06 Manual highlights an installation concept that is focused on safe mounting, equipotential bonding, and proper cable management. The device is designed for indoor use in dry rooms only, and it should be connected using high-shield coaxial cables with F connectors. If the receiver power is not enough to supply the connected LNB, an external power supply such as the SZU 99-06 can be added. That makes the unit adaptable to different system sizes and receiver configurations.

A major advantage is the cascading option. The SPU 58-06 can be part of a larger distribution chain, allowing installers to expand the network step by step. This is useful in multi-room projects where future growth matters. Its compact size also helps when space in the technical cabinet is limited. At the same time, the product keeps the setup tidy by separating trunk outputs and subscriber outputs in a straightforward layout.

Overall, the Axing SPU 58-06 is best described as a reliable, no-nonsense multiswitch for residential signal distribution. It is not designed for outdoor or humid environments, but within the right installation conditions it offers stable performance, good signal handling, and a clear path for expansion.

Notes

  • Use proper grounding before connecting cascade units.
  • Terminate unused outputs with suitable resistors.
  • Check receiver power if the LNB supply is unstable.
  • Installation should follow the Axing SPU 58-06 Manual and local safety rules.
M: OA-GPT-54-NAN

© Copyright 2026 Manual.ly