35c451063b458473e94db0509481f7d2e6e9 page 3
Manufacturer
AXING AG
Gewerbehaus Moskau
8262 Ramsen
EWR contact adress
Bechler GmbH
Am Rebberg 44
78239 Rielasingen
State of the art 2017-09-12
Technical changes, design modifications, errors and misprints are subject to
change without prior notice.
Safety advices:
Installation and repairs to the equipment may only be carried out by
technicians observing the current VDE guidelines. No liability will be
assumed in the case of faulty installation and commissioning.
Before opening the equipment pull out the power plug or remove the
power supply, otherwise there is danger of electrocution. This is also
valid for cleaning the equipment or working on the connections.
Only use the mains cable connected to the device. Never replace any
parts or make any modifications on the mains cable. Otherwise there is a
risk of mortal injury for which we cannot be held liable.
Providing that a serviceable fuse exists, the power plug must be pulled
out before changing the fuse. Defective fuses may only be replaced with
standard compliant fuses that have the same nominal value.
The equipment may only be operated in dry rooms. In humid rooms or
outdoors there is danger of short-circuit (caution: risk of fire) or
electrocution.
To prevent damage to your equipment and to avoid possible peripheral
damages, the devices foreseen for wall mounting may only be installed
on a flat surface.
Choose the location of installation or mounting so that the power plug
can be reached and pulled out of the socket easily in case of danger.
Choose the location of installation or mounting such that children may
not play unsupervised near the equipment and its connections. The
location of installation or mounting must allow a safe installation of all
cables connected. The mains cable as well as feeder lines may not be
damaged or clamped by objects of any kind.
Choose the location of installation or mounting so that under no
circumstances liquids or objects can get into the equipment (e.g.
condensation, water coming from leaking roofs or flowing water, etc.).
Avoid exposure of the equipment to direct sunlight and to other heat
sources (e. g. radiators. other electrical devices, chimney, etc.). Devices
that are equipped with heat sinks or ventilation slots must under no
circum-stances be covered or blocked. Also ensure for a generous air
circulation around the equipment. In this way you avoid possible damage
to the equipment as well as a risk of fire caused by overheating.
Absolutely avoid that cables come near any source of heat (e.g.
radioators, other electrical devices, chimney, etc.).
SPU 1708-06 | SPU 1712-06
SPU 1716-06 | SPU 1724-06
SPU 1732-06
basic-line
Multiswitches /
Cascade units
Operation instructions
Technical data:
Your device is marked with the WEEE symbol (Waste Electronics and
Electrical Equipment). This means that the electrical and electronic
components must not be disposed of as residual waste. Used electrical and
electronic components must be disposed of separately.
WEEE Nr.
DE26869279
Article SPU 1708-06 SPU 1712-06 SPU 1716-06 SPU 1724-06 SPU 1732-06
Frequency range (TERR | SAT) 5…862 MHz | 950…2400 MHz
Number of inputs 17
Number of trunk outputs 17
Subscriber ports 8 12 16 24 32
Tap loss TERR 24 dB ±2 dB 28 dB ±3 dB 32 dB ±3 dB
Tap loss SAT 2...0 dB ±2 dB 3...0 dB ±2 dB 2...0 dB ±2 dB
Max. output level subscriber ports SAT
1
102 dBµV
Switch commands 13/18 V, 0/22 kHz, DiSEqC 1.0
Through loss TERR 3 dB ±1,5 dB 2…5 dB ±1,5 dB 3…5 dB ±1,5 dB
Through loss SAT 1…2 dB ±1,5dB 1…3 dB ±1,5 dB 2,5...5 dB ±1,5 dB
Isolation V®H. >30 dB
Isolation TERR input®SAT. input 30 dB
Ambient temperature range (acc. to EN 60065) -20…+50°C
Current consumption per subscriber port < 52 mA
Max. LNB supply current 1500 mA
Current consumption per subscriber port
(withoutLNB supply)
10 mA
Equipotential bonding connection 4 mm2
Dimensions (W × H × D) appr. 128 x 291 x 63 mm 189 x 291 x 63 mm 308 x 291 x 63 mm
Protection class IP 20
1
3rd order SAT max. EN50083-3 35dB KMA (2 Sender Messmethode)

Chat with your Axing SPU 1708-06 manual using AI

Get instant AI answers from your Axing SPU 1708-06 manual

Ask anything about the Axing SPU 1708-06. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend SPU 1708-06?

Yes No

Frequently Asked Questions

A

It is used to distribute satellite and terrestrial TV/radio signals to multiple rooms in a home installation. It combines several inputs into one structured multiswitch system for subscriber outlets.

Is this answer helpful?

A

The unit features 17 inputs and 8 subscriber ports. It is part of a product family that also includes larger versions with more subscriber connections.

Is this answer helpful?

A

Yes. It supports terrestrial frequencies from 5 to 862 MHz alongside satellite frequencies from 950 to 2400 MHz, making it suitable for mixed reception setups.

Is this answer helpful?

A

Yes. A separate SZU 99-06 power supply is required. It is not included with the unit and must be connected through the DC socket.

Is this answer helpful?

A

No. The device is intended for dry indoor rooms only. Moisture, direct weather exposure, and improper mounting can cause damage or safety risks.

Is this answer helpful?

A

The system should be installed by a qualified technician, grounded properly, and connected with protected coaxial cables. Power must be disconnected before any work is done.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • Supports both satellite and terrestrial signals in one compact distribution device.
  • Offers 17 inputs and 8 subscriber outputs, suitable for organized home installations.
  • Compatible with standard control signals like 13/18 V, 0/22 kHz, and DiSEqC 1.0.
  • Cascade-ready design makes expansion easier in larger multi-room setups.
VS

Disadvantages

  • Requires professional installation and strict safety compliance.
  • Needs a separate power supply, which is not included.
  • Must be used indoors in dry conditions only.
  • Proper grounding and termination accessories are necessary for correct operation.
M: OA-GPT-54-NAN

Product Specification

Satellite Inputs

16

Terrestrial Inputs

1

Outputs

8, 8 (Sat-Loop), 1 (Terrestrial-Loop)

Cascadable

yes

Satellite Positions

4

Dimensions

5.04x11.46x2.48in (WxHxD)

M: OA-GPT-54-NAN

Product Description

Axing SPU 1708-06: Compact SAT Distribution for Multi-Room Installations

The Axing SPU 1708-06 is a practical multiswitch built for distributing satellite and terrestrial signals across a home or small residential network. It is designed for reliable in-house signal routing, making it a useful choice when several rooms need access to TV and radio sources from a central antenna setup. If you are looking for the Axing SPU 1708-06 Manual content in a quick, easy-to-read overview, this model stands out for its straightforward installation concept and solid technical range.

At its core, the unit supports 17 inputs and provides 8 subscriber connections, with additional variants in the same series for larger systems. That makes it suitable for setups where satellite signals from multiple polarizations must be combined with terrestrial reception such as DAB+ or other broadcast services. The operating range covers 5 to 862 MHz for terrestrial signals and 950 to 2400 MHz for satellite signals, which is ideal for typical modern reception environments.

One of the strengths of the SPU 1708-06 is its focus on safe and stable operation. The product details emphasize correct grounding, indoor use only, and professional installation according to relevant standards. These requirements may sound technical, but they also help protect the system from surges, overheating, and signal issues. In practice, that means a cleaner and more dependable distribution setup when the device is installed properly.

The multiswitch also supports common switching commands such as 13/18 V, 0/22 kHz, and DiSEqC 1.0, so it fits well into standard SAT reception systems. Its compact form factor makes it easier to place in technical cabinets or distribution areas where space matters. When used together with the proper power supply and termination accessories, it can form the basis of a neat cascade-ready installation.

Key points

  • Designed for combined satellite and terrestrial signal distribution in residential environments.
  • Supports 17 inputs and 8 subscriber ports for flexible home networking.
  • Works with standard switching signals and common SAT reception setups.
  • Requires grounding, dry indoor placement, and proper termination for best performance.

Notes

  • Use only recommended accessories and termination resistors when expanding the system.
  • Professional installation is strongly advised for safety and reliability.
  • Keep cables protected from heat, moisture, and physical damage.
  • The power supply is required separately for operation.