Manual.ly Logo

Axing SPU 1308-06 Manual

0.0 · 0 Ratings

PDF manual · 4 Pages

English

M: OA-GPT-54-NAN
page

/ 4

Loading...
907ba3188fabe02178660323f348d17d2d45 page 3
Manufacturer
AXING AG
Gewerbehaus Moskau
8262 Ramsen
EWR contact adress
Bechler GmbH
Am Rebberg 44
78239 Rielasingen
State of the art 2017-09-12
Technical changes, design modifications, errors and misprints are subject to
change without prior notice.
Safety advices:
Installation and repairs to the equipment may only be carried out by
technicians observing the current VDE guidelines. No liability will be
assumed in the case of faulty installation and commissioning.
Before opening the equipment pull out the power plug or remove the
power supply, otherwise there is danger of electrocution. This is also
valid for cleaning the equipment or working on the connections.
Only use the mains cable connected to the device. Never replace any
parts or make any modifications on the mains cable. Otherwise there is a
risk of mortal injury for which we cannot be held liable.
Providing that a serviceable fuse exists, the power plug must be pulled
out before changing the fuse. Defective fuses may only be replaced with
standard compliant fuses that have the same nominal value.
The equipment may only be operated in dry rooms. In humid rooms or
outdoors there is danger of short-circuit (caution: risk of fire) or
electrocution.
To prevent damage to your equipment and to avoid possible peripheral
damages, the devices foreseen for wall mounting may only be installed
on a flat surface.
Choose the location of installation or mounting so that the power plug
can be reached and pulled out of the socket easily in case of danger.
Choose the location of installation or mounting such that children may
not play unsupervised near the equipment and its connections. The
location of installation or mounting must allow a safe installation of all
cables connected. The mains cable as well as feeder lines may not be
damaged or clamped by objects of any kind.
Choose the location of installation or mounting so that under no
circumstances liquids or objects can get into the equipment (e.g.
condensation, water coming from leaking roofs or flowing water, etc.).
Avoid exposure of the equipment to direct sunlight and to other heat
sources (e. g. radiators. other electrical devices, chimney, etc.). Devices
that are equipped with heat sinks or ventilation slots must under no
circum-stances be covered or blocked. Also ensure for a generous air
circulation around the equipment. In this way you avoid possible damage
to the equipment as well as a risk of fire caused by overheating.
Absolutely avoid that cables come near any source of heat (e.g.
radioators, other electrical devices, chimney, etc.).
SPU 1308-06 | SPU 1312-06
SPU 1316-06 |SPU 1324-06
SPU 1332-06
basic-line
Multiswitches /
Cascade units
Operation instructions
Technical data:
Your device is marked with the WEEE symbol (Waste Electronics and
Electrical Equipment). This means that the electrical and electronic
components must not be disposed of as residual waste. Used electrical and
electronic components must be disposed of separately.
WEEE Nr.
DE26869279
Article SPU 1308-06 SPU 1312-06 SPU 1316-06 SPU 1324-06 SPU 1332-06
Frequency range (TERR | SAT) 5…862 MHz | 950…2400 MHz
Number of inputs 13
Number of trunk outputs 13
Subscriber ports 8 12 16 24 32
Tap loss TERR 24 dB ±2 dB 28 dB ±3 dB 32 dB ±3 dB
Tap loss SAT 2...0 dB ±2 dB 3...0 dB ±2 dB 2...0 dB ±2 dB
Max. output level subscriber ports SAT
1
102 dBµV
Switch commands 13/18 V, 0/22 kHz, DiSEqC 1.0
Through loss TERR 3 dB ±1,5 dB 2…5 dB ±1,5 dB 3…5 dB ±1,5 dB
Through loss SAT 1…2 dB ±1,5dB 1…3 dB ±1,5 dB 2,5...5 dB ±1,5 dB
Isolation V®H. >30 dB
Isolation TERR input®SAT. input 30 dB
Ambient temperature range (acc. to EN 60065) -20…+50°C
Current consumption per subscriber port < 52 mA
Max. LNB supply current 1500 mA
Current consumption per subscriber port
(withoutLNB supply)
10 mA
Equipotential bonding connection 4 mm2
Dimensions (W × H × D) appr. 128 x 291 x 63 mm 189 x 291 x 63 mm 308 x 291 x 63 mm
Protection class IP 20
1
3rd order SAT max. EN50083-3 35dB KMA (2 Sender Messmethode)

Chat with your Axing SPU 1308-06 manual using AI

Get instant AI answers from your Axing SPU 1308-06 manual

Ask anything about the Axing SPU 1308-06. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend SPU 1308-06?

Yes No

Frequently Asked Questions

A

It is a multiswitch for distributing satellite and terrestrial RF signals inside a building. It helps route signals from LNBs and terrestrial amplifiers to multiple subscriber outlets.

Is this answer helpful?

A

The SPU 1308-06 variant has 8 subscriber ports. Other models in the same series offer more outputs, but this version is the 8-user model.

Is this answer helpful?

A

No. It is intended for dry indoor rooms only. Moisture, rain, and outdoor exposure can cause short circuits, damage, or safety risks.

Is this answer helpful?

A

Yes. It is designed to work in cascaded setups, allowing multiple multiswitch or cascade units to be linked for larger installations.

Is this answer helpful?

A

An SZU 99-06 power supply is required. It is not included and must be connected to the DC socket with the supplied cable.

Is this answer helpful?

A

Equipotential bonding helps prevent dangerous surges and improves safety. It is a required part of proper installation according to the technical guidance.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • Supports both satellite and terrestrial signal distribution in one compact unit.
  • Cascading capability makes it easier to expand larger antenna systems.
  • Standard switching support improves compatibility with common receivers.
  • Designed for professional indoor installations with solid technical specifications.
VS

Disadvantages

  • Requires a separate power supply, which is not included.
  • Installation should be done by a technician, not a casual user.
  • Unused outputs need termination for best results.
  • Must be installed indoors in dry conditions only.
M: OA-GPT-54-NAN

Product Specification

Satellite Inputs

12

Terrestrial Inputs

1

Outputs

8, 6 (Sat-Loop), 1 (Terrestrial Loop)

Cascadable

yes

Satellite Positions

3

Dimensions

5.04x11.46x2.48 in (WxHxD)

M: OA-GPT-54-NAN

Product Description

Axing SPU 1308-06: Practical Multiswitch Performance for Home Signal Distribution

The Axing SPU 1308-06 Manual points to a compact but capable solution for distributing satellite and terrestrial signals within a house. As part of the AXING basic-line series, the SPU 1308-06 is designed for users who need reliable signal routing, stable switching, and clean integration into a larger satellite distribution setup. It supports everyday installation scenarios where several rooms or receiver points must be fed from a central antenna system.

At its core, this multiswitch is built for flexibility. It works with 13 inputs and 13 trunk outputs, and the SPU 1308-06 version offers 8 subscriber ports. The device handles both SAT and terrestrial signals, making it suitable for combined TV and radio distribution, including services such as DAB+ where applicable. Its technical range covers 5 to 862 MHz for terrestrial signals and 950 to 2400 MHz for satellite signals, which aligns well with typical in-house RF distribution needs.

One of the strongest points of this model is its role in structured installations. It can be used on its own or as part of a cascaded system, helping installers expand distribution without rebuilding the whole network. The unit also supports common switching commands such as 13/18 V, 0/22 kHz, and DiSEqC 1.0, which makes it compatible with standard satellite receiver control logic. For larger systems, the cascade-friendly design is especially useful.

Installation quality matters here. The device should be mounted in a dry indoor area, with proper equipotential bonding and careful cable routing. The text emphasizes safety, grounding, and correct termination of unused outputs, all of which help maintain signal quality and reduce interference. A separate SZU 99-06 power supply is required, and the system is intended to be used by qualified installers following technical standards.

In practice, the Axing SPU 1308-06 is a solid choice for users who want dependable signal distribution with professional-grade behavior. It is not a consumer plug-and-play gadget, but rather a well-engineered component for organized satellite and terrestrial installations.

Notes

  • Intended for indoor RF signal distribution only.
  • Terminate unused outputs to maintain performance.
  • Grounding and correct mounting are essential for safe operation.
  • Best suited to professional or experienced installations.