39192891f032bf46e4c253fdc451291d0315 page 3
SES 46-00 | SES 86-00
Unicable multiswitch
Operation Instructions
State of the art 2016-04-18 - Technical changes, design modifications,
errors and misprints are subject to change without prior notice.
Manufacturer
AXING AG
Gewerbehaus Moskau
CH-8262 Ramsen
EWR contact adress
Bechler GmbH
Am Rebberg 44
D-78239 Rielasingen
This symbol indicates that this product is not to be disposed of
with your household waste, according to the WEEE Directive
(2002/96/EC) and your national law.
This product should be handed over to a designated collection
point, e.g., on an authorized one-for-one basis when you buy a
new similar product or to an authorized collection site for
recycling waste electrical and electronic equipment (WEEE).
For more information about where you can drop off your waste
equipment for recycling, please contact your local city office,
waste authority, approved WEEE scheme or your household
waste disposal service.
WEEE Nr.
DE14023300
Safety advice:
· Installation and repairs to the equipment may only be carried out by
technicians observing the current VDE guidelines. No liability will be
assumed in the case of faulty installation and commissioning.
· To prevent damage to your equipment and to avoid possible peripheral
damages, the devices foreseen for wall mounting may only be installed
on a flat surface.
· Choose the location of installation or mounting such that children may
not play unsupervised near the equipment and its connections. The
location of installation or mounting must allow a safe installation of all
cables connected. The mains cable as well as feeder lines may not be
damaged or clamped by objects of any kind.
· If possible - please install the Multiswitch underneath the roof or at any
dry location. If installed open-air, make sure to use watertight
connectors!
Technical specifications:
SES 46-00 SES 86-00
Inputs
SAT 4 8
Subscriber ports 1
Frequency range
SAT 950...2200 MHz
Transmission frequencies 1280 MHz
1382 MHz
1484 MHz
1586 MHz
1688 MHz
1790 MHz
Output level
Subscriber ports 90 dBµV
Operating voltage 12...18 VDC
iInternal current consumption
without LNB 230 mA 300 mA
LNB supply 14 V/18 V
Transient current for LNB max. 500 mA
External switching power
supply unit for LNB SZU 99-22 SZU 99-14

Chat with your Axing SES 46-00 manual using AI

Get instant AI answers from your Axing SES 46-00 manual

Ask anything about the Axing SES 46-00. Answers come from this manual, with the pages they are based on.

Ask a Question

0/1000

Do you recommend SES 46-00?

Yes No

Frequently Asked Questions

A

It is used to distribute satellite, radio, and multimedia signals in a house through a unicable system. The switch converts satellite programs into fixed user-band frequencies so several receivers can share one cable path.

Is this answer helpful?

A

The SES 46-00 is designed for up to six receivers. Each receiver is assigned a specific transmission frequency, which helps avoid conflicts and keeps the installation organized.

Is this answer helpful?

A

No. It requires receivers that fully support EN 50494 unicable operation. Each receiver must be configured with its assigned user ID and transmission frequency.

Is this answer helpful?

A

The switch itself is powered by the connected receivers, but the LNB needs an external switching power supply. The manual notes specific AXING power supply models for this purpose.

Is this answer helpful?

A

Yes, it includes a weather protection housing and can be mounted on an antenna mast or other outdoor location. If installed outside, watertight connectors are essential.

Is this answer helpful?

A

AGC, or automatic gain control, keeps the output signal stable. Even when the input level varies, the subscriber output remains at a consistent 90 dBµV.

Is this answer helpful?

M: OA-GPT-54-NAN

Advantages and Disadvantages

Advantages

  • Supports up to 6 receivers on a single cable system.
  • AGC helps keep output levels stable across different input conditions.
  • Weather-protected housing improves mounting flexibility outdoors.
  • Fixed user-band frequencies simplify receiver setup and cable planning.
VS

Disadvantages

  • Requires EN 50494-compatible receivers to function correctly.
  • Needs an external power supply for LNB operation.
  • Professional installation is recommended, adding setup complexity.
  • Best performance depends on proper socket and cable selection.
M: OA-GPT-54-NAN

Product Specification

Satellite Inputs

4

Terrestrial Inputs

0

Outputs

1 (Unicable)

Unicable

max. 6 participants total

Satellite Positions

1

Dimensions

7.68x4.72x1.18in (WxHxD)

M: OA-GPT-54-NAN

Product Description

Axing SES 46-00 Manual: Smart Unicable Distribution for Satellite Setups

The Axing SES 46-00 is a compact unicable multiswitch designed to simplify satellite signal distribution in home installations. As highlighted in the Axing SES 46-00 Manual, the unit takes signals from a Quattro LNB and converts them into fixed transmission frequencies so multiple receivers can share the same cable path efficiently. This makes it a practical solution for households that want flexible satellite access without complex wiring.

One of the strongest advantages of the SES 46-00 is its support for up to six receivers through predefined user bands. The output frequencies are arranged to work cleanly across the installation, and the highest frequency can be assigned to the receiver closest to the switch to help balance cable loss. This thoughtful design helps maintain stable performance, especially in systems where cable length varies between rooms.

Another useful feature is the automatic gain control. With an input range of 60 to 90 dBµV, the switch keeps the subscriber output steady at 90 dBµV, which helps deliver consistent signal quality. The unit is powered by the connected receivers, while the LNB requires an external power supply, making the system easier to integrate into existing setups.

The SES 46-00 also comes with a weather protection housing, so it can be mounted securely outdoors, such as on an antenna mast, when needed. Installation is intended for trained technicians, and the manual stresses the use of proper coaxial cables, diode-decoupled antenna sockets, and overvoltage protection for reliable operation. When paired with programmable sockets and the AXING programmer, the system becomes even more secure and resistant to interference.

Overall, this multiswitch is aimed at users who need a tidy, scalable, and standards-based unicable solution for distributing TV and radio signals inside the home. It is best suited to EN 50494-compatible receivers and works particularly well where clean signal management and simple receiver access are priorities.

Notes

  • Use only with compatible EN 50494 receivers.
  • Install in a dry location when possible.
  • External LNB power supply is required.
  • Recommended for indoor signal distribution applications only.