Manual.ly Logo

Atika ALE300N Manual

0.0 · 0 Ratings

PDF manual · 144 Pages

English

M: QW-35-FL
page

/ 144

Loading...
8977e3b004bae893d47ce523b43916101ade page d
13
You may not start to operate the machine
until you have read these operating
instructions, observed all the instructions
given and installed the machine as described!
Keep the operating instructions in a safe place for future
use.
Electrical devices do not go into the domestic rubbish.
Give devices, accessories and packaging to an
ecofriendly recycling.
According to the European Directive 2012/19/EU on electrical
and electronic scrap, electrical devices that are no longer
serviceable must be separately collected and brought to a
facility for an environmentally compatible recycling.
C
C
o
o
n
n
t
t
e
e
n
n
t
t
s
s
EC Declaration of Conformity 13
Extent of delivery 13
Symbols on the machine 13
Symbols in the operating instructions 14
Proper use 14
Residual risks 14
Security advices 14
Electrical safety advices 14
Function principle 15
Assembly 15
Location of the air dehumidifier 16
Location 16
Electric supply 16
Power system fuse protection 16
Start-up 16
Before starting up 16
Control panel 17
Powering up 17
Shutting down 17
Setting the humidity 17
Automatic defroster 17
Operating hour counter 17
Water outlet 17
Removing the water collecting container 18
Continuous or extended operation 18
Transport 18
Cleaning and maintenance 19
Cleaning the air filter 19
Removing the filter 19
Inserting the filter 19
Cleaning the device 19
Maintenance 19
Storage 19
Guarantee 19
Possible faults 20
Fault code 20
Technical specifications 21
Wiring diagram 21
Refrigerant circuit 22
Spare parts 22
E
E
C
C
D
D
e
e
c
c
l
l
a
a
r
r
a
a
t
t
i
i
o
o
n
n
o
o
f
f
C
C
o
o
n
n
f
f
o
o
r
r
m
m
i
i
t
t
y
y
No. (Nr. (S-No.): 14761
according to Directive 2014/35/EU
We,
ATIKA GmbH
Josef-Drexler-Str. 8 - 89331 Burgau - Germany
Here with declare under our sole responsibility that the product
Luftentfeuchter (Air dehumidifier) type / model ALE 300 N
Serial number: 000001-020000
is conform with the above mentioned EC directives as well as
with the provisions of the guidelines below:
2014/30/EU and 2011/65/EC
Following harmonized standards have been applied:
EN 60335-1:2012+A11:2014;
EN 60335-2-40:2003+A11:2004+A12:2005+A1:2006+A2:2009+
A13:2012;
EN 62233:2008;
EN 55014-1:2006+A1:2009+A2:2011;
EN 55014-2:1997+A1:2001 +A2:2008;
EN 61000-3-2:2014; EN 61000-3-3:2013.
Keeping of technical documents at:
ATIKA GmbH – Technical department – Josef Drexler Str. 8 -
89331 Burgau – Germany
i.A.
Burgau, 19.12.2016 i.A. G. Koppenstein
Engineering design management
E
E
x
x
t
t
e
e
n
n
t
t
o
o
f
f
d
d
e
e
l
l
i
i
v
v
e
e
r
r
y
y
After unpacking, check the contents of the box for
completeness
possible transport damage.
Report any damage or missing items to your dealer, supplier or
the manufacturer immediately. Complaints made at a later date
will not be acknowledged.
pre-assembled device unit
1 carrying handle
hose
leg right / left
2 wheels
warranty card
1 screw bag
1 operating instruction
manual

Chat with your Atika ALE300N manual using AI

Get instant AI answers from your Atika ALE300N manual

Ask anything about the Atika ALE300N. Answers come from this manual, with the pages they are based on.

ALE300N Maintenance Schedule

Remind me when maintenance is due
Yearly
Internal inspection by service staff

Have the interior of the dehumidifier checked for contamination by customer service once a year or more frequently depending on operating conditions.

Regularly
Clean the air filter

Clean the filter at regular intervals depending on operating conditions. Use a vacuum for slight contamination or wash with lukewarm soapy water (max 40°C) for heavy contamination.

Regularly
Clean the device exterior

Clean the outside of the device regularly with a damp cloth and mild cleaning solution. Ensure no water enters the interior and do not use solvents.

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend ALE300N?

Yes No

Frequently Asked Questions

A

No. Never transport the air dehumidifier lying down or tilted more than 45 degrees. You must let it stand upright for one hour after transport to allow the refrigerant to settle properly before starting it.

Is this answer helpful?

A

Error E4 indicates that the water collecting container is full. The device will stop and make a sound. You need to empty the tank and reinsert it correctly to clear the error.

Is this answer helpful?

A

Yes. Use extension cables complying with IEC 60245. Ensure the wire cross-section is at least 1.5 square millimeters for lengths up to 25 meters.

Is this answer helpful?

A

No. The machine must not be operated by children or young people under 16 years of age. They are not aware of the risks associated with the use of these devices.

Is this answer helpful?

A

Clean it regularly by vacuuming loose dust or washing with soapy water if heavily soiled. Do not expose the wet filter to sunlight to dry as this may damage the material.

Is this answer helpful?

A

Yes. For continuous operation, remove the stopper and attach the hose to allow water to flow freely into a lower drainage system.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • High capacity 30 liters per day for large rooms
  • Automatic defrost function works down to 5 Celsius
  • Durable build quality suitable for home use
  • Easy filter maintenance reduces waste
  • Large tank reduces emptying frequency during use
VS

Disadvantages

  • Heavy weight at 27 kg limits portability
  • Noisy operation below 70 decibels may disturb sleep
  • Limited temperature range starts only above 5 C
  • Single filter type requires specific replacement parts
  • Extension cables need specific cross-sections for safety
M: QW-35-FL

Product Specification

Power

640 W

Color

Orange, Black

Recommended Room Size

Up to 538 sq ft

Power Levels

Yes

Air Circulation

206 CFM

Dehumidification Capacity

63 pints/24h

Refrigerant

R-410A

Operating Temperature

41 deg F to 90 deg F

Water Tank Capacity

1.32 gallons

Filtration

Washable Air Filter

Features

Wheels, Humidistat, Auto Power Off, Direct Condensate Drain Connection

Noise Level

Max 66 dB(A)

Weight

59.52 lbs

M: QW-35-FL

Product Description

Managing Home Humidity Effectively

Controlling moisture levels within your living space is crucial for health and structural integrity. Mold and dampness can cause significant damage to walls and furniture over time. The Atika ALE300N Dehumidifier Manual provides essential guidance for operating this robust unit effectively. This appliance utilizes advanced condensation technology to reduce relative humidity efficiently throughout the day. With a high capacity of 30 liters per 24 hours, it is ideal for medium to large rooms up to 125 cubic meters. It ensures dry conditions by extracting water vapor from the environment continuously.

Key Features and Performance

The device operates on a principle where room air passes through a washable air filter and a cooling element. Water vapor condenses into droplets and is collected in a removable tank. The dried air is heated slightly before returning to the room. This process ensures a comfortable climate without drying out the air excessively. Users can set specific humidity levels between 30% and 90% easily. The control panel displays current humidity and fault codes for troubleshooting. Continuous operation mode allows for extended drying without emptying the tank frequently when connected to a drain.

Maintenance and Assembly

Proper setup is vital for longevity and safety. Ensure the unit stands upright for one hour before starting if transported horizontally to allow refrigerant settling. The water tank has a float switch that triggers an alarm and stops the compressor when full. Cleaning the air filter regularly maintains peak performance and prevents internal contamination. Instructions specify using mild soap for the filter and avoiding harsh chemicals on the casing. Regularly check the hose for kinks to ensure proper water drainage during continuous operation.

Safety and Warranty

Electrical safety is paramount when using high power devices. Use a dedicated outlet with a fault-current circuit breaker for protection. Do not operate outside the 5 to 32 degree Celsius range as the unit will not function correctly. The unit includes an automatic defrost function for lower temperatures down to 5 degrees Celsius to prevent ice buildup. Always refer to the official documentation for warranty details and authorized service contacts. This manual ensures safe operation and optimal results for years to come. Keep the device dry and covered when not in use to extend its lifespan. Regular checks of the power cable and hose connections are recommended before each season. Transport only in an upright position to protect the compressor from damage.

Troubleshooting Common Issues

If the unit fails to start, check the fuse and power connection. Fault codes E3, E4, and E5 indicate sensor or tank issues. E4 specifically means the tank is full. Ensure doors and windows are closed to maximize efficiency. If the room is too cold, the unit may not run. The compressor needs warm air to function optimally. Always unplug the device before cleaning or moving it. This prevents electrical shocks and protects the internal components from damage during transport. The power consumption is rated at 640 watts with a maximum of 770 watts. It features an operating hour counter to track usage time. The sound level is under 70 decibels making it suitable for indoor living areas. The unit weighs 27 kg and comes with wheels for easy mobility.

M: QW-35-FL

© Copyright 2026 Manual.ly