6148beb3ec724d13ec64279dbfd6db0e6d44 page 29
41
4.1 Inadequate draft in the chimney
If you experience poor draft in the stove after the installation, please make sure that there is nothing in the
chimney to restrict the smoke and that no nearby buildings or trees affect the winds around the chimney.
If the chimney is too short, leaks, or is inadequately insulated, there may be problems with the chimney draft
(let the chimney sweep assess this). The draft should be sufficient during the ignition phase when the
stove/chimney is cold to provide a clean combustion and prevent smoke leakage. Therefore, we recommend
a chimney draft around 5 Pa in the ignition phase.
Once the ignition is a success and the smoke temperature is rising, it is important that the chimney draft
reaches a stable area around 18-25 Pa in operation (1 hour after ignition) when the chimney/stove is hot.
The draft in the area of 18-25 Pa when the stove is hot is essential in order to achieve an optimum and clean
combustion. Therefore, we recommend that you measure your chimney draft when the chimney is cold and
when it is hot after 1 hour in operation.
In practice, the chimney draft will differ – especially in cold condition. Therefore, the best indication of the
chimney draft is to measure the draft when it is hot. If the chimney sweep judges the draft to be sufficient, but
you still have problems lighting a fire, try extending the fire lighting phase by using more thin pieces of
kindling and 1-2 firelighters, so that the chimney gets thoroughly warm. The chimney will not draw at
optimum effect until it is warm. When a layer of embers has been formed, add 2-3 dry logs.
If it is impossible to establish a sufficiently natural chimney draft, the chimney can be fitted with a smoke
exhauster, e.g. Aduro DraftOptimizer.
4.2 Chimney and Smoke
If you experience smoke coming out of the stove or the start section of the smoke pipe, it could be due to
certain weather conditions. On stormy or cold winter days or if the chimney has not been used in a while, a
cold plug can be created in the chimney, meaning the natural draft will be at its minimum.
If the chimney is cold and cold plugs are created, you may experience smoke leaks during the ignition and
startup phase. In this situation there can be more smoke than usually in the combustion chamber and some
of it might leak out of the stove. Therefore, if you have a cold chimney that has not been used for a while, we
recommend that you use some wood sticks to heat the chimney and eliminate the cold plug.
5. Maintenance and cleaning of the stove
Pakninger
Med tiden bliver pakningerne slidte og bør derfor efterses. Er de utætte, bør de skiftes.
Combustion chamber
The fireproof tiles in the combustion chamber eventually wear out and should be replaced when the cracks
are more than 0.5 cm. The durability of the tiles depends on how often and how intensively the stove is used.
You can change the tiles yourself. They are available as a ready-to-use set. For further information, go to
www.aduroshop.com.
All maintenance and cleaning of the stove should be carried out when it is
cold.

Chat with your Aduro 9.3 Lux manual using AI

Get instant AI answers from your Aduro 9.3 Lux manual

Ask anything about the Aduro 9.3 Lux. Answers come from this manual, with the pages they are based on.

9.3 Lux Maintenance Schedule

Remind me when maintenance is due
Yearly
Clean interior and flue pipe

Clean the inside of the stove and the flue pipe at least once a year, or more frequently depending on usage intensity.

Show in the manual (page 42)
Before it gets full
Empty the ashpan

Empty the ashpan before it becomes completely full. Always leave a layer of ashes in the bottom to insulate the combustion chamber.

Show in the manual (page 13)
Regularly
Inspect door and glass gaskets

Check that gaskets around the glass and door are intact and soft. Replace them if they are worn or leaking.

Show in the manual (page 28)
As needed
Clean soot from the glass

Remove soot stains using a damp cloth dipped in cold ash or an Aduro Easy Clean pad. Do not use water or solvents on the paint.

Show in the manual (page 42)
Occasionally
Dust the stove surface

Vacuum with a soft brush attachment or wipe with a dry, soft cloth. Do not use spirit or solvents as they remove the paint.

Show in the manual (page 42)
When cracked >0.5cm
Replace vermiculite/fireproof tiles

Replace the fireproof tiles in the combustion chamber when cracks exceed 0.5 cm. Durability depends on frequency and intensity of use.

Show in the manual (page 41)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend 9.3 Lux?

Yes No

Frequently Asked Questions

A

Yes, you can extend the warranty from two years to five years by registering online within five months of purchase. Visit the official website to complete the free online registration process to activate the extended coverage terms.

Is this answer helpful?

A

The stove is designed for dry wood and wood briquettes. Moisture content should not exceed 18 kg. Split hardwood stored outdoors under cover for at least one year is recommended for optimal combustion and efficiency.

Is this answer helpful?

A

Clean the glass using a damp cloth dipped in cold ash from the stove. Do not use water or standard cleaning agents on the glass. You may also use Aduro Easy Clean pads which do not scratch the surface like other tools.

Is this answer helpful?

A

Yes, the Aduro 9.3 Lux is equipped for external combustion air supply. This connects from outside directly to the combustion chamber via a channel under the unit, helping ensure air flow in tightly sealed energy efficient modern houses.

Is this answer helpful?

A

You may install the stove yourself, but local regulations often require consultation with a chimney sweep. They must approve the installation and sign the certificate. Always follow national and European installation standards strictly.

Is this answer helpful?

A

The Aduro 9.3 Lux features a nominal power of 6.0 kW. It is suitable for heating buildings with optimum insulation up to 150 square meters, average insulation up to 100 square meters, or poor insulation up to 60 square meters.

Is this answer helpful?

A

The Aduro-tronic is a manual mechanical startup device that regulates combustion air automatically without electricity. It limits primary air intake after loading wood, helping achieve cleaner burning and reduced fuel usage automatically.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • High energy efficiency class A+ with 81.3% power output.
  • Aduro-tronic system reduces wood consumption by up to 40%.
  • Nordic Ecolabel ensures environmentally responsible manufacturing.
  • Optional external air supply for modern tight homes.
VS

Disadvantages

  • Heavy weight of 108 kg requires strong floor support.
  • Installation must be approved by local chimney sweep.
  • Strict distance requirements from combustible materials apply.
  • Paint may discolor if stove is overloaded with too much wood.
M: QW-35-FL

Product Specification

Type

Wood Stove

Rated Heat Output

20,473 BTU/hr

Color

Black

Material

Steel

Fuel

Wood, Wood Briquettes, Lignite

Heating Capacity

Up to 1,614.59 sq ft

Capacity

Log Length 15.35 inches

Efficiency

>81.3%

Features

Ash Container (Removable), Airwash, Fuel Automation

Mounting Type

Freestanding

Dimensions

19.69x44.88x18.03 inches (WxHxD)

Flue Connection

5.91 inches (Diam)

Weight

238.10 lbs

M: QW-35-FL

Product Description

Discover the Aduro 9.3 Lux Experience

Welcome to a new era of heating efficiency and cozy comfort. The Aduro 9.3 Lux brings warmth and style to your home while maintaining a sleek design. This wood burning stove meets high European standards like EN13240. It carries the Nordic Ecolabel ensuring environmental responsibility throughout production. You will find detailed instructions in the Aduro 9.3 Lux Manual. Reading it thoroughly ensures maximum safety and optimal performance over the years. Skipping these steps can lead to operational issues.

Power and Efficiency

This stove delivers 6.0 kW of nominal power effectively. It reaches an energy efficiency class of A+ for low emissions. The design includes primary, secondary, and tertiary air supplies for clean burning. A unique feature is the patent pending Aduro tronic system. This mechanical startup regulates combustion automatically without electricity usage. You get optimal burning results and up to 40 percent less wood consumption. The robust construction uses sheet iron for long lasting durability. Maximum recommended wood length is 39 cm for best airflow.

Installation and Safety

Installation requires careful planning and attention to detail. You must follow all local rules and regulations strictly. Consult your local chimney sweep before starting the work officially. Distances to combustible materials are critical for safety compliance. Maintain 15 cm behind and 70 cm to the side of the unit. If placing near flammable floors like wood, use a non flammable base. External air supply is a vital option for very tight modern homes. This helps supply fresh air for combustion in sealed buildings. Ensure the chimney draft is sufficient before lighting. It should be around 18 to 25 Pa when warm for stability. Ensure floor strength as the unit is heavy.

Maintenance and Care

Keep your stove looking new for many years. The surface uses heat resistant Senotherm paint effectively. Vacuum regularly or dust with a soft dry cloth often. Do not use water on the outside surface ever. Clean the glass with cold ash and a damp cloth gently. Check gaskets periodically for leaks or wear and tear signs. Replace fireproof tiles if cracks exceed 0.5 cm in size. Always empty the ashpan when the stove is completely cold to avoid burns. First ignitions may produce odor as paint hardens.

Notes for Owners

  • Register online to extend warranty to five years.
  • Use dry wood with under 18 percent moisture content.
  • Never use fossil fuels or treated wood products inside.
  • Transport the unit upright or pad loose parts carefully.
  • Measure chimney draft when cold and after one hour hot.

By following these guidelines, you maximize your investment in heating. Enjoy the warm flames safely with peace of mind for your family. Proper care ensures the unit functions like the day you bought it.

M: QW-35-FL