4b9f4c91ee1dcc8e910471217fb486a1a1f7 page 20
32
Congratulations on your new Aduro Stove!
To get the best possible experience and benefit from your new Aduro wood burning stove, it is important that
you read the user manual thoroughly through before you install the stove and start using it. Errors or
incorrect settings can cause hazardous conditions and/or poor operation.
For further information, please go to www.adurofire.com.
5-year warranty – Free online registry
You have the opportunity to extend the warranty on your wood burning stove from two to five years for free.
All you need to do is register the stove at www.adurofire.com/warranty. The deadline for registering is five
months from the date of purchase.
Production number
The wood stove has a production number on the rating plate on the back of the stove. We recommend that
you note down this number in the box below before mounting the wood stove. For the purposes of the
guarantee and for other enquiries, it is important that you are able to quote this number.
Enjoy!
HOW TO SUCCEED WITH YOUR NEW WOOD STOVE
In our customer service center Aduro Customer Service you will
find tips and tricks on how to succeed with your new Aduro wood
burning stove. Here you will have direct access to interesting
content about installation and maintenance of your stove as well
as support related information. Find us here and make the most of
your Aduro wood stove.
UK

Chat with your Aduro 9 air manual using AI

Get instant AI answers from your Aduro 9 air manual

Ask anything about the Aduro 9 air. Answers come from this manual, with the pages they are based on.

9 air Maintenance Schedule

Remind me when maintenance is due
Yearly
Clean the inside of the stove and flue pipe

Remove the exhaust deflector to clean the combustion chamber and flue pipe. Frequency depends on usage; perform at least once a year.

Show in the manual (page 44)
Regularly
Inspect and replace door and glass gaskets

Check gaskets around the glass and door for wear or leaks regularly. Replace them if they are no longer tight or damaged.

Show in the manual (page 44)
As needed
Replace worn fireproof tiles in combustion chamber

Inspect vermiculite tiles and replace them when cracks exceed 0.5 cm. Durability depends on frequency and intensity of use.

Show in the manual (page 43)
Before full
Empty the ash pan

Empty the ash pan before it gets completely full. Always leave a layer of ashes in the bottom to insulate the chamber and aid lighting.

Show in the manual (page 44)
Occasionally
Dust or vacuum the stove surface

Clean the painted exterior with a soft dry cloth or vacuum with a soft brush attachment. Do not use water, spirit, or solvents.

Show in the manual (page 44)
After installation
Tighten glass fittings

It is common maintenance to tighten the glass fittings shortly after the stove has been installed and checked initially.

Show in the manual (page 43)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend 9 air?

Yes No
0
User Pic

Lars Nielsen

7 months ago

Does this stove work well with limited room ventilation?

0
User Pic

Manual.ly

7 months ago

Yes, the stove draws well and is ideal for rooms with ventilation. Users report good performance and beautiful design in similar conditions.

M: QW-35-FL
M: QW-35-FL

Frequently Asked Questions

A

You can extend the warranty from two years to five years by registering your product online. You must complete the form within five months of your purchase date to qualify for this service. This is free of charge for eligible units and covers manufacturing defects for a longer period.

Is this answer helpful?

A

You should use dry seasoned hardwood stored outdoors for at least one year under cover. Wood moisture must not exceed eighteen percent to ensure efficient burning. Split logs with a maximum length of 39 cm work best and provide optimal heat output.

Is this answer helpful?

A

Yes, the stove supports external air supply for tight modern homes. You connect a channel directly to the combustion chamber to draw fresh air from outside. This ensures proper ventilation and prevents negative pressure issues in your house indoors.

Is this answer helpful?

A

Ideally, the chimney draft should be between eighteen to twenty-five Pascal when the stove is hot. In cold conditions during ignition, a draft of five Pascal is recommended. If natural draft is insufficient, you may install a smoke exhauster.

Is this answer helpful?

A

Empty the ash pan before it becomes completely full to maintain airflow efficiency. Always leave a layer of ash at the bottom to insulate the combustion chamber. Cleaning the interior stoves and flue pipe should be done at least once a year.

Is this answer helpful?

A

Ensure clearances from flammable materials are strictly followed per local regulations. You must use a non-flammable base beneath the unit due to its weight. Consult a chimney sweep before using to certify the installation meets all safety codes.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • High energy efficiency class of A plus ensures minimal fuel usage and lower heating costs over time.
  • Aduro-tronic system automates air intake and reduces wood consumption by up to forty percent automatically.
  • External air supply option allows for efficient combustion in modern tightly sealed homes efficiently.
  • 5 year warranty extension available through simple online registration process upon purchase.
  • Heat resistant Senotherm paint protects the surface up to 500 degrees allowing easy repairs later.
VS

Disadvantages

  • Heavy weight of 103 kg requires a very sturdy and reinforced floor installation base.
  • Requires consistent chimney draft between 18 to 25 Pascal for optimal combustion performance.
  • Regular maintenance of seals and ash pan is required to ensure longevity and safety standards.
  • Not designed for fossil fuels only specific wood and briquettes are approved for safe burning.
  • Warranty becomes void if unauthorized changes or improper installation practices are not followed strictly.
M: QW-35-FL

Product Specification

Type

Wood Stove

Rated Output

6 kW

Color

Black

Material

Steel

Fuel

Wood, Wood Briquettes, Lignite

Heating Area

Up to 1614.59 sq ft

Log Length

15.35 inches

Efficiency

>81.30%

Features

Ash container (removable), Glass washer, Fuel automation

Mounting Type

Freestanding

Dimensions

19.69x37.72x17.60 in (WxHxD)

Flue Outlet

5.91 in (Ø)

Weight

227.08 lbs

M: QW-35-FL

Product Description

Discover the Comfort of the Aduro 9 Air

The Aduro 9 Air represents exceptional warmth and efficiency for modern homes seeking sustainable heating solutions. This wood burning stove is designed to meet strict European environmental standards while providing reliable year round performance. When you invest in an Aduro 9 Air, you are choosing quality craftsmanship and long term durability. Understanding your appliance is crucial for safety and enjoyment. This guide covers the essentials related to the Aduro 9 Air Manual to help you get started with confidence and ease.

Key Features and Performance

The stove boasts a nominal power of 6.0 kW, capable of heating spaces up to 150 meters squared with optimal insulation. It achieves an impressive energy efficiency class of A plus. The innovative Aduro-tronic system automates air intake, reducing wood consumption by up to forty percent without requiring electricity. This mechanical automation simplifies daily operation significantly. The advanced glass wash system keeps the front view clear of soot throughout the entire burn cycle. You will appreciate the clean look and efficient heat distribution around your room.

Installation and Safety Guidelines

Proper placement requires specific clearances from flammable materials to ensure home safety. Always adhere to local regulations regarding chimney sweeps and formal installation certifications before use. The unit weighs 103 kg, requiring a sturdy, non-flammable base to support the load safely. Installation must account for chimney draft, ideally between eighteen to twenty-five Pascal in warm conditions for optimal draft. External air supply is available for tight modern homes to ensure proper combustion indoors without pressure issues.

Fuel Selection and Maintenance

Dry seasoned wood is essential for best results and minimal emissions during operation. Wood moisture should not exceed eighteen percent to prevent creosote buildup and inefficient burning inside the chamber. The stove utilizes split hardwood stored outdoors for at least one year under cover for best performance. Regular cleaning of the ash pan and inspection of seals are necessary for longevity and safety. The Senotherm paint resists heat up to five hundred degrees, allowing easy touch-ups if needed later for cosmetics.

Warranty and Support

Registering your product online extends the warranty from two years to five years easily upon purchase. Keep your production number safe for future reference regarding service or spare parts orders. This commitment reflects the manufacturers confidence in durability and overall quality assurance. Enjoy the warmth and ambiance of your new heating solution while following operational tips for the best experience every winter season ahead. Always read the manual instructions regarding specific local safety codes.

Notes on Usage

First lighting requires care to ensure longevity. Use packaging wood if possible for initial burns. Avoid using volatile liquids to start fires ever. Keep door closed during operation except for initial moments during lighting. Ensure vents remain clear for airflow at all times. Check seals regularly for leaks.

M: QW-35-FL

© Copyright 2026 Manual.ly