4.1 Inadequate draft in the chimney
If you experience poor draft in the stove after the installation, please make sure that there is nothing in the
chimney to restrict the smoke and that no nearby buildings or trees affect the winds around the chimney.
If the chimney is too short, leaks, or is inadequately insulated, there may be problems with the chimney draft
(let the chimney sweep assess this). The draft should be sufficient during the ignition phase when the
stove/chimney is cold to provide a clean combustion and prevent smoke leakage. Therefore, we recommend
a chimney draft around 5 Pa in the ignition phase.
Once the ignition is a success and the smoke temperature is rising, it is important that the chimney draft
reaches a stable area around 18-25 Pa in operation (1 hour after ignition) when the chimney/stove is hot.
The draft in the area of 18-25 Pa when the stove is hot is essential in order to achieve an optimum and clean
combustion and avoid problems such as pellet accumulation and smoke leakage. Therefore, we recommend
that you measure your chimney draft when the chimney is cold and when it is hot after 1 hour in operation.
In practice, the chimney draft will differ – especially in cold condition. Therefore, the best indication of the
chimney draft is to measure the draft when it is hot. If the chimney sweep judges the draft to be sufficient, but
you still have problems lighting a fire in “wood mode”, try extending the fire lighting phase by using more thin
pieces of kindling and 1-2 firelighters, so that the chimney gets thoroughly warm. The chimney will not draw
at optimum effect until it is warm. When a layer of embers has been formed, add 2-3 dry logs.
If it is impossible to establish a sufficiently natural chimney draft, the chimney can be fitted with a smoke
exhauster, e.g. Aduro DraftOptimizer.
4.2 Chimney and Smoke
If you experience smoke coming out of the stove or the start section of the smoke pipe, it could be due to
certain weather conditions. On stormy or cold winter days or if the chimney has not been used in a while, a
cold plug can be created in the chimney, meaning the natural draft will be at its minimum.
If the chimney is cold and cold plugs are created, you may experience smoke leaks during the ignition and
startup phase. In this situation there can be more smoke than usually in the combustion chamber and some
of it might leak out of the stove. Therefore, if you have a cold chimney that has not been used for a while, we
recommend that you use some wood sticks to heat the chimney and eliminate the cold plug.
5. Maintenance and cleaning of the stove
Pakninger
Med tiden bliver pakningerne slidte og bør derfor efterses. Er de utætte, bør de skiftes.
Combustion chamber
The fireproof tiles in the combustion chamber eventually wear out and should be replaced when the cracks
are more than 0.5 cm. The durability of the tiles depends on how often and how intensively the stove is used.
You can change the tiles yourself. They are available as a ready-to-use set. For further information, go to
www.aduroshop.com.
All maintenance and cleaning of the stove should be carried out when it is
cold.

Chat with your Aduro 17 manual using AI

Get instant AI answers from your Aduro 17 manual

Ask anything about the Aduro 17. Answers come from this manual, with the pages they are based on.

17 Maintenance Schedule

Remind me when maintenance is due
Yearly
Clean stove interior and flue pipe

Clean the inside of the stove and the flue pipe at least once a year, or more frequently depending on usage intensity.

Show in the manual (page 42)
Before it gets full
Empty the ashpan

Empty the ashpan before it becomes completely full. Always leave a layer of ashes in the bottom to insulate the combustion chamber.

Show in the manual (page 42)
Regularly
Inspect door and glass gaskets

Check that gaskets around the glass and door are intact and soft. Replace them if they are worn or leaky.

Show in the manual (page 42)
When cracked >0.5cm
Replace fireproof tiles

Replace vermiculite/fireproof tiles in the combustion chamber when cracks exceed 0.5 cm.

Show in the manual (page 41)
As needed
Clean glass pane

Remove soot stains using a damp cloth dipped in cold ash or an Aduro Easy Clean pad. Do not use water or solvents.

Show in the manual (page 42)
Occasionally
Dust stove exterior surface

Vacuum with a soft brush attachment or dust with a dry soft cloth. Do not use spirit or solvents as they damage the paint.

Show in the manual (page 42)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend 17?

Yes No

Frequently Asked Questions

A

You can extend the warranty from two to five years by registering your stove online at the official Aduro website within five months of purchase. Ensure you have your production number ready for registration.

Is this answer helpful?

A

Use dry split hardwood stored outdoors under cover for at least one year. The moisture content must not exceed 18 percent to ensure efficient burning and prevent excessive emissions or soot buildup.

Is this answer helpful?

A

While self-installation is permitted, it is strongly recommended to consult a professional chimney sweep. You are responsible for ensuring all local building codes and safety standards are met before using the stove.

Is this answer helpful?

A

The Aduro-tronic is a mechanical device that automatically regulates primary air intake after you manually open it when adding wood. It closes the damper gradually over about six minutes to optimize combustion without electricity.

Is this answer helpful?

A

Smoking during lighting often indicates a cold chimney causing a cold plug. Heat the chimney first using kindling and small pieces of wood until the draft stabilizes before adding larger logs.

Is this answer helpful?

A

The interior and flue pipe should be cleaned at least once a year, or more frequently depending on usage intensity. Always ensure the stove is completely cool before performing any cleaning tasks.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • Aduro-tronic system reduces firewood usage by up to 40 percent through automatic air regulation
  • Compliance with strict European environmental standards including the Nordic Ecolabel
  • External air supply option available for use in tightly sealed modern energy-efficient homes
  • Heat-resistant paint allows for easy surface repair if scratches occur over time
  • Flexible flue outlet design allows for top or rear pipe connection configurations
VS

Disadvantages

  • Requires precise adjustment of air dampers to avoid overheating and potential paint damage
  • Must strictly use dry wood with moisture below 18 percent to maintain warranty and efficiency
  • Initial setup requires consulting local regulations and potentially a certified chimney sweep
  • Wear parts like gaskets and firebricks are not covered under the standard two-year warranty
  • Heavy weight of 108 kg necessitates a floor capable of supporting significant load
M: QW-35-FL

Product Specification

Type

Wood stove

Rated heating output

6.5 kW

Color

Black

Material

Steel

Fuel type

Wood

Room heating capacity

Up to 1614 sq ft

Capacity

Log length 15.35 in

Efficiency

>78%

Features

Removable ash drawer, glass cleaning system, automatic fuel feed

Installation type

Freestanding

Dimensions

19.69x38.66x17.83 in (WxDxH)

Flue connection

5.91 in (Ø)

Weight

238.10 lbs

M: QW-35-FL

Product Description

Discover the Aduro 17 Manual: Your Guide to Efficient Heating

The Aduro 17 Manual serves as an essential companion for anyone looking to maximize the performance and longevity of their new wood-burning stove. This comprehensive guide covers every aspect of ownership, from initial unboxing and safe installation to daily operation and long-term maintenance. By following the instructions within this manual, users can ensure they are operating their stove in accordance with European standards like EN13240 while enjoying the warmth and ambiance of a clean burn.

At the heart of the Aduro 17 is the innovative Aduro-tronic system. This patented mechanical device regulates combustion air automatically without needing electricity. It simplifies the firing process by managing primary air intake, allowing users to achieve up to 40% less firewood consumption compared to traditional stoves. The manual details how to activate this feature during lighting and stoking phases to maintain optimal efficiency.

Installation requires careful attention to safety distances from flammable materials and proper chimney connection. The text provides specific measurements for clearance behind, above, and beside the unit to prevent fire hazards. It also explains how to configure the flue outlet for either top or rear discharge, ensuring compatibility with various home setups. For modern, energy-efficient homes that may lack sufficient natural air, the manual outlines the procedure for connecting external combustion air supplies.

Proper fuel selection is critical for performance. The guide recommends using dry hardwood with a moisture content below 18%, stored outdoors under cover for at least one year. Burning wet or treated wood can damage the stove and reduce efficiency. The manual offers practical tips on lighting fires, maintaining glows, and cleaning glass surfaces with ash or specialized pads. Regular maintenance tasks, such as checking gaskets and replacing worn firebricks, are clearly described to keep the appliance running smoothly for years.