Once the ignition is a success and the smoke temperature is rising, it is important that the chimney draft
reaches a stable area around 18-25 Pa in operation (1 hour after ignition) when the chimney/stove is hot.
The draft in the area of 18-25 Pa when the stove is hot is essential in order to achieve an optimum and clean
combustion. Therefore, we recommend that you measure your chimney draft when the chimney is cold and
when it is hot after 1 hour in operation.
In practice, the chimney draft will differ – especially in cold condition. Therefore, the best indication of the
chimney draft is to measure the draft when it is hot. If the chimney sweep judges the draft to be sufficient, but
you still have problems lighting a fire, try extending the fire lighting phase by using more thin pieces of
kindling and 1-2 firelighters, so that the chimney gets thoroughly warm. The chimney will not draw at
optimum effect until it is warm. When a layer of embers has been formed, add 2-3 dry logs.
If it is impossible to establish a sufficiently natural chimney draft, the chimney can be fitted with a smoke
exhauster, e.g. Aduro DraftOptimizer.
4.2 Chimney and Smoke
If you experience smoke coming out of the stove or the start section of the smoke pipe, it could be due to
certain weather conditions. On stormy or cold winter days or if the chimney has not been used in a while, a
cold plug can be created in the chimney, meaning the natural draft will be at its minimum.
If the chimney is cold and cold plugs are created, you may experience smoke leaks during the ignition and
startup phase. In this situation there can be more smoke than usually in the combustion chamber and some
of it might leak out of the stove. Therefore, if you have a cold chimney that has not been used for a while, we
recommend that you use some wood sticks to heat the chimney and eliminate the cold plug.
5. Maintenance and cleaning of the stove
Pakninger
Med tiden bliver pakningerne slidte og bør derfor efterses. Er de utætte, bør de skiftes.
Combustion chamber
The fireproof tiles in the combustion chamber eventually wear out and should be replaced when the cracks
are more than 0.5 cm. The durability of the tiles depends on how often and how intensively the stove is used.
You can change the tiles yourself. They are available as a ready-to-use set. For further information, go to
www.aduroshop.com.
Glass
Wet wood, unsatisfactory chimney draft, and wrong use of the stove can leave soot stains on the glass pane.
They can easily be removed using a damp cloth that you dip in cold ash and rub on the sooty glass. Special
cleaning agents are also available to remove soot from glass, e.g. the Aduro Easy Clean pad. The pad
neither scratch nor damage the glass and is for multiple usage. Water or other cleaning agents are not
necessary.
All maintenance and cleaning of the stove should be carried out when it is
cold.

Chat with your Aduro 15.3 manual using AI

Get instant AI answers from your Aduro 15.3 manual

Ask anything about the Aduro 15.3. Answers come from this manual, with the pages they are based on.

15.3 Maintenance Schedule

Remind me when maintenance is due
Semiannual
Check and tighten glass fittings

It is common maintenance to tighten glass fittings shortly after installation and to check that gaskets are properly placed.

Show in the manual (page 38)
Yearly
Clean stove interior and flue pipe

Clean the inside of the stove and flue pipe at least once a year or more frequently if needed. This can be done by removing the baffle plate and cleaning through the door or cleaning aperture.

Show in the manual (page 38)
As needed
Inspect and replace gaskets

Gaskets around glass and door wear with time. Inspect regularly for leaks and replace them if they are damaged or leaking.

Show in the manual (page 38)
As needed
Replace combustion chamber tiles

Fireproof tiles in the combustion chamber wear out and should be replaced when cracks exceed 0.5 cm. Durability depends on usage intensity.

Show in the manual (page 38)
Every use
Empty ashpan

Empty the ashpan before it gets completely full. Always leave a layer of ashes in the bottom to insulate the chamber and aid ignition.

Show in the manual (page 38)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: QW-35-FL

Ask a Question

0/1000

Do you recommend 15.3?

Yes No

Frequently Asked Questions

A

Use seasoned wood and wood briquettes. Recommended: split hardwood stored outdoors under cover ~1 year, moisture ≤ 18%. Max log length 50 cm. Do not burn painted, treated wood, chipboard, paper or waste; fossil fuels are prohibited.

Is this answer helpful?

A

Aduro-tronic is a mechanical start-up automation requiring no electricity. It holds primary air open during ignition and automatically closes it over ~6 minutes, optimizing combustion, simplifying operation and potentially reducing wood consumption by up to 40%. Closure speed is adjustable with a small Allen key.

Is this answer helpful?

A

Recommended chimney draft: approx. 18–25 Pa when hot for clean combustion. Aim for about 5 Pa during cold ignition. If natural draft is insufficient, consider a smoke exhauster (e.g. Aduro DraftOptimizer) and consult your chimney professional.

Is this answer helpful?

A

Regularly inspect and replace door and glass gaskets, and firebricks when cracked >0.5 cm. Empty ashpan when not full (wait until embers are cold). Clean the stove interior and flue at least annually or more often depending on use; use original spare parts only.

Is this answer helpful?

A

Self-installation is allowed but consult local regulations and your chimney sweep. Distance to combustible materials: rear 20 cm (12 cm with insulated flue), side 34/11 cm, top 75 cm, and furniture 120 cm. Minimum stove bottom height: 24 cm above floor; use non-combustible floor protection where required.

Is this answer helpful?

A

Check baffle plate and internal parts, use packaging wood for initial fires, ventilate the room (first firings may emit odors as paint cures), warm up gradually, keep the door ajar during initial firing and avoid aggressive fires for the first 2–3 uses.

Is this answer helpful?

A

Register the stove online within the manufacturer’s specified period (usually within five months of purchase) at the provided warranty URL for your country to extend the warranty from two to five years.

Is this answer helpful?

M: OA-GPT-5-NAN

Advantages and Disadvantages

Advantages

  • High efficiency (78%) and Energy Class A for clean, effective heating
  • Nordic Ecolabel and compliance with EN13240/NS3058 for environmental and safety standards
  • Aduro-tronic mechanical automation improves ignition and reduces wood usage up to 40%
  • Flexible flue options (top or rear 150 mm) and wall-mounting with supplied bracket
  • Easy maintenance with replaceable firebricks, accessible flue cleaning, and touch-up paint available
VS

Disadvantages

  • Requires correct chimney draft (recommended 18–25 Pa when hot) or optional draft optimizer
  • Overfiring ( > ~3.1 kg/h) can damage lacquer and void warranty for related defects
  • Installation and clearances must meet local regulations; may need professional inspection
  • Regular maintenance and correct dry fuel (≤18% moisture) required for optimal performance
  • Weight (84 kg) and wall-mounting demand suitable structural support and proper fixings
M: OA-GPT-5-NAN

Product Specification

Type

Wood burning stove

Nominal heat output

22,158.92 BTU/h

Color

black

Material

Steel

Fuel

Wood

Room heating capacity

up to 1,614.58 sq ft

Capacity

Log length 19.69 in

Efficiency

>78%

Special features

Ash pan (removable), Air wash system, Automatic fuel feed

Mounting type

Wall mounting

Dimensions

30.67x24.72x14.88 in (WxHxD)

Pipe connection

5.91 in (Diameter)

Weight

185.20 lb

M: OA-GPT-54-NAN

Product Description

Aduro 15.3 — Efficient, certified wood stove

The Aduro 15.3 is a modern convection wood stove designed for reliable home heating with environmental responsibility and user-friendly operation. Boasting a nominal output of 6.5 kW, 78% efficiency and Energy Class A, it suits homes with varying insulation levels and can heat spaces up to roughly 150 m² in optimally insulated buildings. Built from robust sheet iron and weighing 84 kg, the unit accepts logs and briquettes up to 50 cm, uses a 150 mm flue connection (top or rear), and supports both convection heating and an air-wash system to help keep the viewing glass clear.

Key features and usability

Aduro 15.3 meets EN13240 and NS3058 standards and carries the Nordic Ecolabel, reflecting strong emissions and production credentials. It includes primary, secondary and tertiary air supplies to manage ignition, sustained burn and combustion of flue gases. The stove integrates the Aduro-tronic mechanical start-up automation (no electricity required) to modulate primary air and improve combustion efficiency — potentially reducing wood consumption by up to 40% when used correctly. Installation can be wall-mounted with supplied bracket; clear distance and floor protection rules apply for safe placement.

Operation guidance emphasizes intermittent firing (burn down to embers before reloading), use of well-seasoned hardwood (moisture ≤ 18%), and correct air control: keep secondary and tertiary air active during burning and use the Aduro key for easier secondary damper adjustments. Proper first-time heat cycles, gradual warm-up, and ventilation/adequate chimney draft (recommended operating draft 18–25 Pa when warm) are important for clean combustion and avoiding smoke issues.

Maintenance is straightforward: inspect and replace gaskets and firebricks as they wear, empty the ashpan safely (wait for embers to cool), and perform annual cleaning of stove internals and flue. Surface touch-ups are simple with heat-resistant Senotherm paint. Only original spare parts should be used; unauthorized modifications void specifications and may affect safety and warranty. A free warranty extension to five years is available via online registration within the specified timeframe.

Notes

  • Use dry, split hardwood (max 50 cm, ~10 cm diameter preferred) and avoid painted, treated or waste materials.
  • Ensure adequate fresh air supply to the room (approx. 25 m3/h) to prevent underpressure and poor combustion.
  • Measure chimney draft cold and after one hour hot; consider a flue optimizer if natural draft is insufficient.
  • Follow local codes and have installation inspected by your chimney sweep where required.