Manual.ly Logo

Aduro 1.1 Manual

0.0 · 0 Ratings

PDF manual · 95 Pages

English

M: QW-35-FL
page

/ 95

Loading...
97e13a623a91bd62ac4439c5a25d3e1db53a page 1e
30
Congratulations on your new Aduro Stove!
To get the best possible experience and benefit from your new Aduro wood burning stove, it is important that
you read the user manual thoroughly through before you install the stove and start using it. Errors or
incorrect settings can cause hazardous conditions and/or poor operation.
For further information, please go to www.adurofire.com.
5-year warranty – Free online registry
You have the opportunity to extend the warranty on your wood burning stove from two to five years for free.
All you need to do is register the stove at www.adurofire.com/warranty. The deadline for registering is five
months from the date of purchase.
Production number
The wood stove has a production number on the rating plate on the back of the stove. We recommend that
you note down this number in the box below before mounting the wood stove. For the purposes of the
guarantee and for other enquiries, it is important that you are able to quote this number.
Enjoy!
HOW TO SUCCEED WITH YOUR NEW WOOD STOVE
In our customer service center Aduro Customer Service you will
find tips and tricks on how to succeed with your new Aduro wood
burning stove. Here you will have direct access to interesting
content about installation and maintenance of your stove as well
as support related information. Find us here and make the most of
your Aduro wood stove.
UK

Chat with your Aduro 1.1 manual using AI

Get instant AI answers from your Aduro 1.1 manual

Ask anything about the Aduro 1.1. Answers come from this manual, with the pages they are based on.

1.1 Maintenance Schedule

Remind me when maintenance is due
Yearly
Clean the inside of the stove and flue pipe

Remove soot from the combustion chamber and smoke outlet. Perform more often if the stove is used frequently.

Show in the manual (page 41)
Regularly
Inspect door and glass gaskets

Check seals for wear or leaks regularly. Replace them if they are damaged or no longer airtight.

Show in the manual (page 41)
As needed
Replace fireproof tiles

Replace vermiculite or fireproof stones in the combustion chamber when cracks exceed 0.5 cm.

Show in the manual (page 41)
Before full
Empty the ash pan

Empty the ash drawer before it becomes completely full, leaving a thin layer of ash at the bottom for insulation.

Show in the manual (page 41)
Occasionally
Dust the exterior surface

Vacuum with a soft brush or wipe with a dry cloth. Do not use water, spirit, or solvents on the painted surface.

Show in the manual (page 41)

Free maintenance reminders

Timed to your purchase date. Always free, unsubscribe anytime.

By submitting you agree to the privacy policy. Unsubscribe with one click in any email.
M: qwen/qwen3.8-flash

Ask a Question

0/1000

Do you recommend 1.1?

Yes No

Frequently Asked Questions

A

Register online within five months of purchase at www.adurofire.com/warranty to get five years for free instead of two years standard.

Is this answer helpful?

A

Wood moisture must not exceed 18 percent for optimal combustion and efficiency levels recommended by the manufacturer.

Is this answer helpful?

A

It is a mechanical start-up device that manually regulates primary air without the need for external electricity connections.

Is this answer helpful?

A

Yes, but you must consult a chimney sweep and ensure all local regulations are followed before starting use.

Is this answer helpful?

A

Use packaging wood, heat slowly, and ensure ventilation as the paint hardens and odors may occur initially.

Is this answer helpful?

A

Use a damp cloth with cold ash or a specialized cleaning pad like Aduro Easy Clean to avoid scratches.

Is this answer helpful?

A

Ideal draft is 18 to 25 Pa when hot and around 5 Pa during the ignition phase for clean burning.

Is this answer helpful?

M: QW-35-FL

Advantages and Disadvantages

Advantages

  • High energy efficiency rating at 81.2 percent for reliable heat
  • Extended 5-year warranty available upon free online registration
  • Nordic Ecolabel guarantees strict environmental compliance quality
  • Aduro-tronic system automates airflow regulation manually without electricity
  • Dual flue exit options provide flexible installation possibilities
VS

Disadvantages

  • Requires specific chimney draft between 10 to 25 Pascal for use
  • Initial installation demands consulting a certified chimney sweep
  • Regular maintenance of gaskets needed to prevent potential leaks
  • First fire may cause odors during the paint curing phase
  • Must use strictly dry wood under 18 percent moisture content
M: QW-35-FL

Product Specification

Type

Wood Stove

Nominal Heat Output

6 kW

Color

Black

Material

Steel

Fuel

Wood, Coal

Room Heating Capacity

Up to 1,614.59 sq ft

Storage Capacity

Log Length 14.17 in

Efficiency

>81.2%

Features

Ash container (removable), Glass wash, Fuel automation

Installation Type

Freestanding

Dimensions

19.69x39.96x17.72 in (WxHxD)

Flue Outlet

5.91 in (diam.)

Weight

209.44 lbs

M: QW-35-FL

Product Description

Experiencing the Aduro 1.1 Heating Experience

Welcome to the world of efficient heating with the Aduro 1.1. This stove represents a significant step forward in home warmth and style for many homeowners. Owners often refer to the detailed Aduro 1.1 Manual to maximize performance and ensure safety during daily operation. The guide emphasizes strict adherence to national installation regulations before first use. It highlights the importance of reading all instructions carefully before mounting the unit. Installing this unit requires attention to local rules and chimney sweeps approval. Ensure your chimney meets draft specifications for optimal airflow and cleanliness. The stove complies with EN13240 European standards effectively. It features a Nordic Ecolabel for environmental protection compliance and quality.

The heating capacity reaches a nominal six kilowatts power output. This suits well-insulated homes effectively depending on insulation levels. You can cover up to one hundred fifty square meters comfortably in good conditions. Energy efficiency is rated at eighty-one percent overall for heat extraction. This helps reduce fuel consumption significantly over the winter cold season. The Aduro-tronic system automatically regulates airflow without external electricity. You simply add dry wood and activate the mechanism manually. It minimizes user work while maximizing heat output consistently.

Maintenance involves regular checks of seals, gaskets, and the glass pane. Glass cleaning requires specific care to avoid scratches on the front surface. Ash removal must happen strictly when the unit is completely cold and safe. Safety is paramount during operation and cleaning processes. Never burn treated wood or fossil fuels inside the combustion chamber. Always use dry timber under eighteen percent moisture content limits. Installation allows flexibility with either top or rear flue exits for pipes. Stone cladding adds aesthetic value to living spaces significantly. The soapstone variant offers a classic look for serious enthusiasts. Weight varies depending on the chosen configuration and stone options available. Proper spacing from flammable materials prevents hazardous situations indoors. Consult your chimney sweep for final approval before starting operation.

Online registration extends warranty terms effectively for new owners. Five years of coverage provides peace of mind for all new buyers. In case of issues, retain all purchase receipts and registration details immediately. Keep production numbers handy for future support inquiries or claims. Customer service centers offer technical tips and troubleshooting advice. This stove brings reliable comfort to any modern home environment effectively. Proper lighting ensures the best combustion results initially. Use kindling for the first few fires to heat the flue. The paint hardens during initial use and may cause odors. Ensure ventilation in the room during this specific period. The manual details all nuances of air dampers for control. Primary air lights the fire while secondary air keeps it clean. Tertiary air burns smoke gases for better efficiency. Follow these steps for maximum satisfaction.

Notes

  • Always check the manual before burning.
  • Maintain proper draft levels.
M: QW-35-FL

© Copyright 2026 Manual.ly