ABB JA/S 4.SMI.1M Manual
PDF manual · 88 Pages
English

Quick check
Incorrect answer, please try again.
Chat with your ABB JA/S 4.SMI.1M manual using AI
Get instant AI answers from your ABB JA/S 4.SMI.1M manual
Ask anything about the ABB JA/S 4.SMI.1M. Answers come from this manual, with the pages they are based on.
Ask a Question
Do you recommend JA/S 4.SMI.1M?
Yes NoFrequently Asked Questions
JA/S 4.SMI.1M is designed for 230 V SMI blind or shutter drives. SJR/S 4.24.2.1 is designed for 24 V SMI LoVo drives. Both provide four independent SMI outputs and similar KNX automation functions.
Is this answer helpful?
Each output can control up to four compatible SMI drives connected in parallel as a group. The actuator automatically handles drive addressing, so separate SMI commissioning is not normally required.
Is this answer helpful?
Yes. Outputs can move coverings to percentage positions and, for blind operation, set slat angles. Four preset positions per output can be recalled and updated through KNX commands.
Is this answer helpful?
The actuators can respond to wind, rain, and frost alarms, locking commands, and forced control. Each function can move the covering up, down, stop it, or select a preset position. Priorities are configurable.
Is this answer helpful?
Yes. Front-panel controls allow local up, down, stop, and blind slat adjustment during manual mode. LEDs show output status, movement direction, safety conditions, and communication faults.
Is this answer helpful?
Configuration uses ETS with the appropriate ABB application program. Parameters can be assigned individually per output or applied to all outputs, which can reduce setup time in larger installations.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- Four independent outputs, each supporting up to four compatible SMI drives in parallel.
- Precise position and slat control supports blinds, shutters, awnings, and other coverings.
- Automatic drive addressing simplifies replacement and group operation.
- Sun, heating, cooling, wind, rain, frost, scene, and safety functions support advanced automation.
- Local buttons, LEDs, status objects, and diagnostics aid testing and troubleshooting.
Disadvantages
- JA/S and SJR/S support different drive voltages, so correct model selection is essential.
- Installation, wiring, motor limit setup, and ETS configuration require qualified professionals.
- More than four drives on one output restricts normal KNX functions to safety and alarm operation.
- Weather alarms and output delays require careful parameter planning to avoid unsuitable movement timing.
- The devices must be installed in a closed distribution enclosure and operate within specified conditions.
Product Specification
Type
Actuator
Standard
KNX
Function
Switch actuator (on/off), blind control
Topology
Bus
Dimensions
2.83 x 3.54 x 2.54 in
Features
IP20
Product Description
ABB JA/SJR - Read, Download & Print Free
ABB JA/SJR SMI blind and roller shutter actuators bring precise, flexible shading control to ABB i-bus KNX installations. Designed for modern residential, commercial, and public buildings, these DIN rail devices manage blinds, shutters, awnings, and similar coverings through the Standard Motor Interface (SMI). Their digital control approach supports accurate positioning, dependable feedback, and coordinated building automation.
Four-channel SMI control
Both actuator versions provide four independent outputs. Each output can control a group of up to four compatible drives connected in parallel, allowing installers to manage multiple coverings as one zone. The JA/S 4.SMI.1M is intended for 230 V SMI drives, while the SJR/S 4.24.2.1 supports 24 V SMI LoVo drives. This distinction helps planners select the appropriate model for the installed motor system.
The actuators automatically recognize and address compatible SMI drives, reducing setup effort when drives are added or replaced. SMI compatibility also enables products from supported manufacturers to be combined within the same installation. Position and slat-angle feedback can be made available through KNX, helping users and building systems maintain a clear view of operating status.
Flexible comfort and safety functions
ABB JA/SJR supports direct up, down, stop, and slat adjustment commands. Blinds can move to exact percentage positions, while up to four preset positions per output allow frequently used settings to be recalled or updated. Scene control adds another layer of convenience, with each output able to participate in multiple building scenes.
Automation functions help improve comfort and energy performance. Sun protection control can react to sunlight, while heating and cooling automation can position coverings to support solar gains in colder periods or reduce heat buildup during warmer conditions. Adjustable delays prevent unnecessary movement during rapidly changing weather.
Safety functions can prioritize wind, rain, and frost alarms, as well as locking and forced-control commands. These settings can move coverings to a defined safe position and block normal operation when required. Configurable priorities ensure that the most important condition determines actuator behavior.
Installation and local operation
The compact four-module housing mounts on a standard 35 mm DIN rail in a distribution enclosure. Front-mounted buttons allow local operation during testing or service, and LEDs indicate movement, end positions, manual mode, alarms, and SMI communication issues. Configuration is completed with ETS and the corresponding ABB application.
Note: Installation, wiring, and commissioning must be carried out by qualified electrical professionals. Motor end limits must be set before operation, and 230 V must never be connected to SMI control lines.
Note: For dependable weather monitoring, set alarm supervision times substantially longer than the weather sensor transmission interval.