Do you recommend DLR/A 4.8.1.1?
Yes NoFrequently Asked Questions
No, control is exclusively group-orientated via 8 lighting groups.
Is this answer helpful?
Up to 4 light sensors LF/U 2.1 can be connected for constant control.
Is this answer helpful?
Yes, it is used for grouping and addressing without needing ETS initially.
Is this answer helpful?
Devices can be set to resume previous brightness or default power-on levels.
Is this answer helpful?
Yes, including time curves and warning phases before lights turn off.
Is this answer helpful?
Yes, coded fault messages are sent individually for each device on the KNX.
Is this answer helpful?
Dimensions are 147 x 202 x 50 mm for surface mounting in distribution boards.
Is this answer helpful?
Advantages and Disadvantages
Advantages
- Supports up to 64 DALI devices per output for extensive coverage.
- Enables constant lighting control with up to 4 integrated light sensors.
- Simplifies commissioning with an independent Software Tool requiring no ETS.
- Offers master-slave functionality for advanced brightness offset applications.
- Provides individual fault diagnostics for every connected DALI device.
Disadvantages
- Overlapping lighting groups are not supported by the firmware.
- Requires separate KNX and auxiliary supply voltage for full functionality.
- Staircase lighting uses up two predefined scene slots in the memory.
- Calibration for constant lighting must be performed manually via software.
- Programming parameters cannot be edited using ETS version 2 software.
Product Specification
Type
Actuator
Standard
KNX
Function
Switch actuator (on/off), dimming function
Topology
Bus
Dimensions
7.95 x 5.79 x 1.97 inches
Features
IP54
Product Description
Transform Your Lighting Control with the ABB DLR/A4.8.1.1
The modern building automation landscape demands flexibility and efficiency. The ABB DLR/A4.8.1.1 stands out as a powerful solution for integrating digital lighting interfaces into KNX systems. This surface-mounted device combines the international standards of DALI with the intelligence of the KNX protocol. This versatile hardware simplifies the transition from older lighting systems. By bridging these two technologies, facility managers can achieve energy-efficient and constant lighting control effortlessly.
Installing this controller allows you to connect up to sixty-four DALI devices directly to a single output. These devices can be organized into eight lighting groups, providing granular control over different areas within a building. Unlike traditional setups, KNX control is implemented exclusively through these lighting groups, ensuring streamlined operation. One of the standout features is the capability for constant lighting control. With support for up to four light sensors, the system maintains optimal brightness levels automatically, adapting to natural daylight changes throughout the day. This ensures a comfortable working environment while reducing energy waste.
Energy conservation is a key benefit. Automatic occupancy detection combined with intelligent dimming significantly reduces operating costs. The hardware supports various advanced functions such as staircase lighting time curves and scene recall. You can store and activate fourteen independent light scenes using simple telegrams. Furthermore, the built-in burn-in function ensures new lamps reach their full potential before regular dimming commences, extending their lifespan. Fault messages regarding lamp malfunctions are available individually for each lighting group or device on the KNX bus.
Commissioning is simplified through an independent Software Tool. Managers without deep ETS knowledge can readdress devices or assign groups easily. Safety remains paramount, with the device featuring clear status LEDs for operation readiness and faults. Installation requires standard DIN mounting rails and plug-in terminals, making integration into distribution boards straightforward. The unit is designed for suspended ceilings or underfloor installations. It also features IP 54 protection for reliable operation in demanding environments. It accepts both AC and DC auxiliary power supplies to generate the necessary DALI voltage.
Compatibility extends beyond basic switching. Master-slave operations allow for brightness offsets, enabling complex lighting scenarios where multiple strips share control logic. The internal fuse protects against unintended mains voltage connections to the DALI output. Regular maintenance is minimal due to the durable design. Monitoring tools help identify issues quickly without physical inspection of every bulb. The device supports flexible light sensor assignment to control circuits.
Notes
Ensure all voltage supplies are disconnected during installation. Always use the latest application software version for programming. The device operates within specific temperature ranges to maintain reliability. Proper sensor placement avoids direct sunlight interference.